EM260-DEV Ember, EM260-DEV Datasheet - Page 80

KIT DEV FOR EM260

EM260-DEV

Manufacturer Part Number
EM260-DEV
Description
KIT DEV FOR EM260
Manufacturer
Ember
Series
InSightr
Type
802.15.4/Zigbeer

Specifications of EM260-DEV

Frequency
2.4GHz
For Use With/related Products
EM260
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
636-1005
EM260
80
120-1003-000D
Name: pollForData
Description: Periodically request any pending data from our parent. Setting
BER_EVENT_INACTIVE will generate a single poll.
Command Parameters:
int16u interval
EmberEventUnits units
int8u failureLimit
Response Parameters:
EmberStatus status
Name: pollCompleteHandler
Description: Indicates the result of a data poll to the parent of the local node.
This frame is a response to the
Response Parameters:
EmberStatus status
Name: pollHandler
Description: Indicates that the local node received a data poll from a child.
This frame is a response to the
Response Parameters:
EmberNodeId childId
callback
callback
command.
command.
The node ID of the child that is requesting data.
ID: 0x42
The time between polls. Note that the timer clock is free run-
ning and is not synchronized with this command. This means that
the time will be between
The units for
The number of poll failures that will be tolerated before a
pollCompleteHandler
result in a callback for every poll. Any status value apart from
EMBER_SUCCESS and EMBER_MAC_NO_DATA is counted as a
failure.
The result of sending the first poll.
ID: 0x43
An EmberStatus value: EMBER_SUCCESS - Data was received in
response to the poll. EMBER_MAC_NO_DATA - No data was
pending. EMBER_DELIVERY_FAILED - The poll message could not
be sent. EMBER_MAC_NO_ACK_RECEIVED - The poll message was
sent but not acknowledged by the parent.
ID: 0x44
interval
.
callback is generated. A value of zero will
interval
interval
and (
interval - 1
to 0 or
units
to EM-
).

Related parts for EM260-DEV