Specifications of EM260-USART-JMP-R

Frequency
2.4GHz
For Use With/related Products
EM260
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
636-1004
EM260-JMP
Name: energyScanResultHandler
Description: Reports the result of an energy scan for a single channel. The scan is not complete until the
scanCompleteHandler
This frame is a response to the
Response Parameters:
int8u channel
int8u maxRssiValue
Name: networkFoundHandler
Description: Reports that a network was found, and gives the network parameters useful for deciding which
network to join.
This frame is a response to the
Response Parameters:
int8u channel
int16u panId
boolean expectingJoin
int8u stackProfile
Name: scanCompleteHandler
Description: Returns the status of the current scan. EMBER_SUCCESS signals that the scan has completed.
Other error conditions signify a failure to scan on the channel specified.
This frame is a response to the
Response Parameters:
int8u channel
EmberStatus status
Name: stopScan
Description: Terminates a scan in progress.
Command Parameters: None
Response Parameters:
EmberStatus status
callback is called.
callback
callback
callback
command.
command.
command.
The PAN ID of the current network.
ID: 0x48
The 802.15.4 channel number that was scanned.
The maximum RSSI value found on the channel.
ID: 0x1B
The 802.15.4 channel number on which the current network was
found.
Whether the node that generated this beacon is allowing addi-
tional children to join to its network.
The ZigBee profile number of the current network.
ID: 0x1C
The channel on which the current error occurred. Undefined for
the case of EMBER_SUCCESS.
The error condition that occurred on the current channel. Value
will be EMBER_SUCCESS when the scan has completed.
ID: 0x1D
An EmberStatus value indicating success or the reason for fail-
ure.