E3X-DA41-N Omron, E3X-DA41-N Datasheet - Page 17

PREWIRED DIGITAL PNP FO AMP

E3X-DA41-N

Manufacturer Part Number
E3X-DA41-N
Description
PREWIRED DIGITAL PNP FO AMP
Manufacturer
Omron
Series
E3X-DA-Nr
Type
Photoelectric Sensorr
Datasheets

Specifications of E3X-DA41-N

Output Type
PNP
Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Current - Supply
40mA
Mounting Type
DIN Rail
Output
PNP
Light Source
Red LED
Connection
Prewired Cable
Output Configuration
PNP
Sensor Output
PNP
Sensor Input
Fiber Optic
Supply Voltage Max
24V
Supply Voltage Min
12V
Fiber Optic Sensor Type
Photoelectric Sensor
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XDA41N

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-DA41-N
Manufacturer:
OMRON
Quantity:
374
Amplifier Unit Connectors
Installation
Connector installation
1. Insert the Master or Slave Connector into the amplifier unit
2. Link amplifier units to each other after the master and slave
3. Apply the supplied seal to the non-connecting surface of the
Note: Apply seal to the grooved side.
Removing Connectors
1. Slide the slave amplifier unit (s) on which the connector
2. After the amplifier unit (s) has been separated, press down
E3X-DA-N
until it clicks into place.
Connectors have been inserted.
master/slave connector.
must be removed from the rest of the group.
the lever on the connector and remove it. (Do not attempt
to remove connectors without separating them from other
amplifier units first.)
Sticker
Insert
Press down
Sticker
Remove
Lever
Mounting End Plate (PFP-M)
Depending on the installation, an amplifier unit may move dur-
ing operation. In this case, use an end plate.
Before installing an end plate, remove the clip from the master
amplifier unit using a nipper or similar tool.
The sensor bottom is also equipped with a clip removing
mechanism.
1. Insert the clip to be removed into the slit underneath the clip
2. Remove the clip by rotating the amplifier unit.
When fitting the Mobile Console, set the end plate in the guide
as shown in the following figure.
Tensile stress for connectors (including cables)
E3X-CN11, E3X-CN21, E3X-CN22: 30 N max.
E3X-CN12: 12N max.
on another amplifier unit.
Rotate
Clip
End Plate
A-435