MAX16048ACB+ Maxim Integrated Products, MAX16048ACB+ Datasheet - Page 45

no-image

MAX16048ACB+

Manufacturer Part Number
MAX16048ACB+
Description
IC EE-PROG SYS MGR 8CH 64-TQFP
Manufacturer
Maxim Integrated Products
Type
System Managerr
Datasheets

Specifications of MAX16048ACB+

Number Of Voltages Monitored
8
Output
Open Drain, Push-Pull
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
Adjustable/Selectable
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
64-TQFP Exposed Pad, 64-eTQFP, 64-HTQFP, 64-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The reset output, RESET, is asserted during power-
up/power-down and deasserts following the reset time-
out period once the power-up sequence is complete.
The power-up sequence is complete when any MON_
inputs assigned to Slot 12 exceed their undervoltage
thresholds. If no MON_ inputs are assigned to Slot 12,
the power-up sequence is complete after the slot
sequence delay is expired.
Table 26. EEPROM Fault Log Operation Period
Table 27. RESET Configuration and Dependencies
System Managers with Nonvolatile Fault Registers
REGISTER/
FAULT CONTROL
ADDRESS
EEPROM
REGISTER
19h
r47h[1:0]
12-Channel/8-Channel EEPROM-Programmable
00
01
10
11
______________________________________________________________________________________
BIT RANGE
[1:0]
[6:4]
[2]
[3]
[7]
Failed lines and ADC values saved
RESET OUTPUT CONFIGURATION
00 =
threshold
01 =
threshold
10 =
threshold
11 =
thresholds
0 =
1 =
0 =
1 =
RESET TIMEOUT
000 = 25µs
001 = 3ms
010 = 37.5ms
011 = 150ms
100 = 300ms
101 = 600ms
110 = 1200ms
111 = 2400ms
Reserved
No information saved
ADC values saved
Failed lines saved
DESCRIPTION
is an active-low output
is an active-high output
is an open-drain output
is a push-pull output
is asserted if at least one of the selected inputs exceeds its undervoltage
is asserted if at least one of the selected inputs exceeds its early warning
is asserted if at least one of the selected inputs exceeds its overvoltage
is asserted if any of the selected inputs exceeds undervoltage or overvoltage
RESET
RESET is a configurable output that monitors selected
MON_ voltages during normal operation. RESET also
depends on any monitoring input that has one or more
critical fault enable bits set. Use r19h[1:0] to configure
RESET to assert on an overvoltage fault, undervoltage
fault, or both. Use r19h[3:2] to configure RESET as an
active-high/active-low push-pull/open-drain output. If
desired, configure GPIO4 as a manual reset input, MR,
and pull MR low to assert RESET. RESET includes a
programmable timeout. See Table 27 for RESET depen-
dencies and configuration registers.
DESCRIPTION
MINIMUM REQUIRED SHUTDOWN PERIOD
(ms)
306
252
N/A
90
45

Related parts for MAX16048ACB+