MAX16031ETM+ Maxim Integrated Products, MAX16031ETM+ Datasheet - Page 30

IC SYSTEM MON EEPROM 48-TQFN

MAX16031ETM+

Manufacturer Part Number
MAX16031ETM+
Description
IC SYSTEM MON EEPROM 48-TQFN
Manufacturer
Maxim Integrated Products
Type
Multi-Voltage Supervisorr
Datasheet

Specifications of MAX16031ETM+

Number Of Voltages Monitored
8
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
8 Selectable Threshold Combinations
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFN Exposed Pad
Manual Reset
Resettable
Watchdog
No Watchdog
Supply Voltage (max)
14 V
Supply Voltage (min)
2.9 V
Supply Current (typ)
3000 uA
Maximum Power Dissipation
2222.2 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EEPROM-Based System Monitors
with Nonvolatile Fault Memory
Table 11. Fault Flags
30
REGISTER
ADDRESS
50h
51h
52h
53h
______________________________________________________________________________________
ADDRESS
MEMORY
EEPROM
D0h
D1h
D2h
D3h
RANGE
[7:4]
BIT
[0]
[1]
[2]
[3]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
1 = Short circuit detected at remote temperature sensor 1.
1 = Open circuit detected at remote temperature sensor 1.
1 = Short circuit detected at remote temperature sensor 2.
1 = Open circuit detected at remote temperature sensor 2.
Not used.
1 = IN1 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN2 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN3 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN4 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN5 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN6 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN7 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN8 conversion result exceeds primary overvoltage or undervoltage thresholds.
1 = IN1 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = IN2 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = IN3 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = IN4 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = IN5 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = IN6 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = IN7 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = IN8 conversion result exceeds secondary overvoltage or undervoltage thresholds.
1 = Internal temperature sensor conversion exceeds its primary overtemperature threshold.
1 = Remote temperature sensor 1 conversion exceeds its primary overtemperature threshold.
1 = Remote temperature sensor 2 conversion exceeds its primary overtemperature threshold.
1 = Internal temperature sensor conversion exceeds its secondary overtemperature threshold.
1 = Remote temperature sensor 1 conversion exceeds its secondary overtemperature
threshold.
1 = Remote temperature sensor 2 conversion exceeds its secondary overtemperature
threshold.
1 = Current-sense conversion exceeds its primary overcurrent threshold.
1 = Current-sense conversion exceeds its secondary overcurrent threshold.
DESCRIPTION