Multi-Voltage Supervisorr
Datasheet

Specifications of MAX16031ETM+

Number Of Voltages Monitored
8
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
8 Selectable Threshold Combinations
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFN Exposed Pad
Manual Reset
Resettable
Watchdog
No Watchdog
Supply Voltage (max)
14 V
Supply Voltage (min)
2.9 V
Supply Current (typ)
3000 uA
Maximum Power Dissipation
2222.2 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MAX16031
37, 38
21
22
23
24
25
26
27
28
29
33
34
36
41
42
43
44
45
46
48
PIN
MAX16032
37, 38
21
22
24
25
26
27
28
29
33
34
36
45
46
48
______________________________________________________________________________________
FAULT2 Configurable Open-Drain Fault Output 2
FAULT1 Configurable Open-Drain Fault Output 1
OVERC
OVERT
ALERT
RESET
NAME
DXN2
DXN1
DXP2
DXP1
TMS
TDO
DBP
CS+
TCK
ABP
V
TDI
CS-
IN1
EP
CC
SMBus Alert Open-Drain Output. ALERT follows the SMBALERT# signal functionality
described in Appendix A of the SMBus 2.0 Specification. ALERT asserts when the device
detects a fault, thereby interrupting the host processor to query which device on the serial
bus detected faults.
Overtemperature, Open-Drain Output. OVERT asserts when an overtemperature condition is
detected.
Overcurrent, Open-Drain Output. OVERC asserts when the primary overcurrent threshold is
exceeded.
Configurable Open-Drain Reset Output
JTAG Test Mode Select Input. Internally pulled up to V DBP with a 10kΩ resistor.
JTAG Test Clock Input
JTAG Test Data Input. Internally pulled up to V DBP with a 10kΩ resistor.
JTAG Test Data Output
Internal Digital Voltage Regulator Output. Connect a 1µF bypass capacitor from DBP to
GND. Do not use DBP to power external circuitry.
Internal Analog Voltage Regulator Output. Connect a 1µF bypass capacitor from ABP to
GND. Do not use ABP to power external circuitry.
Device Power Supply. Bypass V CC to GND with a 1µF capacitor.
Current-Sense Negative Input. Must be biased between 3V to 28V for proper operation.
Current-Sense Positive Input. Must be biased between 3V to 28V for proper operation.
Remote Diode 2 Negative Input. If remote sensing is not used, connect DXP2 to DXN2.
Remote Diode 2 Positive Input. If remote sensing is not used, connect DXP2 to DXN2.
Remote Diode 1 Negative Input. If remote sensing is not used, connect DXP1 to DXN1.
Remote Diode 1 Positive Input. If remote sensing is not used, connect DXP1 to DXN1.
Supply Monitor Input 1. IN1 is internally sampled by the ADC. It is configurable for unipolar/
bipolar and single-ended/pseudo-differential. In pseudo-differential mode, IN1 and IN2 form
the + and - of the differential pair. Each input must stay within the specified ADC IN_ voltage
range.
Exposed Pad. Connect EP to ground. EP is internally connected to GND. Do not use as the
main ground connection.