TS921IPT STMicroelectronics, TS921IPT Datasheet - Page 8

IC OP AMP R-R SINGLE 8-TSSOP

TS921IPT

Manufacturer Part Number
TS921IPT
Description
IC OP AMP R-R SINGLE 8-TSSOP
Manufacturer
STMicroelectronics
Datasheet

Specifications of TS921IPT

Amplifier Type
General Purpose
Number Of Circuits
1
Output Type
Rail-to-Rail
Slew Rate
1.3 V/µs
Gain Bandwidth Product
4MHz
Current - Input Bias
15nA
Voltage - Input Offset
3000µV
Current - Supply
1mA
Current - Output / Channel
80mA
Voltage - Supply, Single/dual (±)
2.7 V ~ 12 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP
Number Of Channels
1
Voltage Gain Db
90.88 dB
Common Mode Rejection Ratio (min)
60 dB
Input Offset Voltage
3 mV
Operating Supply Voltage
3 V, 5, V, 9 V
Supply Current
1.5 mA
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
-3db Bandwidth
-
Lead Free Status / Rohs Status
 Details
Other names
497-8136-2
TS921IPT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TS921IPT
Manufacturer:
MURATA
Quantity:
15 339
Part Number:
TS921IPT
Manufacturer:
ST
Quantity:
8 000
Part Number:
TS921IPT
Manufacturer:
ST
0
Company:
Part Number:
TS921IPT
Quantity:
8 000
Company:
Part Number:
TS921IPT
Quantity:
8 000
Macromodels
3
3.1
3.2
8/14
Macromodels
Important note concerning this macromodel
Please consider following remarks before using this macromodel:
In
presented.
Electrical characteristics from macromodelization
Table 5.
Symbol
Section 3.3
I
source
GBP
V
V
V
I
A
I
SR
V
All models are a trade-off between accuracy and complexity (i.e. simulation time).
Macromodels are not a substitute to breadboarding; rather, they confirm the validity of a
design approach and help to select surrounding component values.
A macromodel emulates the NOMINAL performance of a TYPICAL device within
SPECIFIED OPERATING CONDITIONS (i.e. temperature, supply voltage, etc.). Thus the
macromodel is often not as exhaustive as the datasheet, its goal is to illustrate the main
parameters of the product.
Data issued from macromodels used outside of its specified conditions (Vcc, Temperature,
etc) or even worse: outside of the device operating conditions (Vcc, Vicm, etc) are not
reliable in any way.
sink
CC
icm
OH
OL
m
vd
io
Electrical characteristics resulting from macromodel simulation at V
V
R
No load, per operator
R
R
V
V
R
R
R
DD
, the electrical characteristics resulting from the use of these macromodels are
O
O
L
L
L
L
L
L
= 10k
= 10k
= 10k
= 600k
= 10k , C
= 600k
= 3V
= 0V
= 0V, R
L
L
, C
= 100pF
L
connected to V
Conditions
CC/2
, T
amb
= 25°C (unless otherwise specified)
-0.2 to 3.2
Value
2.95
200
1.2
1.3
25
80
80
68
0
4
Degrees
CC
V/mV
MHz
V/ s
Unit
TS921
mV
mA
mV
mA
mA
V
V
= 3V,

Related parts for TS921IPT