Specifications of MCHC908GR8VFAE

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM
Number Of I /o
21
Program Memory Size
7.5KB (7.5K x 8)
Program Memory Type
FLASH
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 6x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
32-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCHC908GR8VFAE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Configuration Register (CONFIG)
Technical Data
132
NOTE:
NOTE:
LVI5OR3 — LVI 5V or 3V Operating Mode Bit
SSREC — Short Stop Recovery Bit
Exiting stop mode by pulling reset will result in the long stop recovery.
If using an external crystal oscillator, do not set the SSREC bit.
When the LVISTOP is enabled, the system stabilization time for power
on reset and long stop recovery (both 4096 CGMXCLK cycles) gives a
delay longer than the enable time for the LVI. There is no period where
the MCU is not protected from a low power condition. However, when
using the short stop recovery configuration option, the 32-CGMXCLK
delay is less than the LVI’s turn-on time and there exists a period in
startup where the LVI is not protecting the MCU.
STOP — STOP Instruction Enable Bit
COPD — COP Disable Bit
Freescale Semiconductor, Inc.
LVI5OR3 selects the voltage operating mode of the LVI module. See
Low-Voltage Inhibit
should match the operating V
LVI’s voltage trip points for each of the modes.
SSREC enables the CPU to exit stop mode with a delay of 32
CGMXCLK cycles instead of a 4096-CGMXCLK cycle delay.
STOP enables the STOP instruction.
COPD disables the COP module. See
(COP).
For More Information On This Product,
1 = LVI operates in 5V mode.
0 = LVI operates in 3V mode.
1 = Stop mode recovery after 32 CGMXCLK cycles
0 = Stop mode recovery after 4096 CGMXCLKC cycles
1 = STOP instruction enabled
0 = STOP instruction treated as illegal opcode
1 = COP module disabled
0 = COP module enabled
Configuration Register (CONFIG)
Go to: www.freescale.com
(LVI). The voltage mode selected for the LVI
DD
. See
Electrical Specifications
Computer Operating Properly
MC68HC908GR8 — Rev 4.0
MOTOROLA
for the

Related parts for MCHC908GR8VFAE