HD64F7044F28V Renesas Electronics America, HD64F7044F28V Datasheet - Page 100

IC SUPERH MCU FLASH 112QFP

HD64F7044F28V

Manufacturer Part Number
HD64F7044F28V
Description
IC SUPERH MCU FLASH 112QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7040r
Datasheets

Specifications of HD64F7044F28V

Core Processor
SH-2
Core Size
32-Bit
Speed
28.7MHz
Connectivity
EBI/EMI, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
74
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
112-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F7044F28V
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
HD64F7044F28V
Manufacturer:
RENESAS
Quantity:
10
Part Number:
HD64F7044F28V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F7044F28V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 4 Instruction Features
There are several restrictions on repeat control:
1. At least one instruction must come between the SETRC instruction and the first instruction of
2. Execute the SETRC instruction after executing the LDRS and LDRE instructions.
3. When there are more than four instructions for the repeat program (loop) and there is no repeat
4. When there are three or fewer instructions in the loop, branch instructions (BRA, BSR, BT,
Table 4.33 PC Values Pushed Out (1)
Conditions
RC>=2
RC=1
5. If there are four or fewer instructions in the loop, branched instructions (BRA, BSR, BT, BF,
Table 4.34 PC Values Pushed Out (2)
Conditions
RC>=2
RC=1
Rev. 5.00 Jun 30, 2004 page 84 of 512
REJ09B0171-0500O
RptEnd:
the repeat program (loop).
start address (in the above example, it was address instr1) at the long word boundary, one cycle
stall (cycle awaiting execution) is required for each repeat.
BF, BT/S, BF/S, BSRF, RTS, BRAF, RTE, JSR, JMP), repeat control instructions (SETRC,
LDRS, LDRE), SR, RS, and RE load instructions, and TRAPA cannot be used. If they are
described, error exemption processing is started and the address values shown in table 4.33 are
pushed out to the stack area pointed by R15.
BT/S, BF/S, BSRF, RTS, BRAF, RTE, JSR, JMP), repeat control instructions (SETRC,
LDRS, LDRE), SR, RS, and RE load instructions, and TRAPA cannot be used for the last
three instructions in the repeat program (loop). If they are described, error exception
processing is started and the address values shown in table 4.34 are pushed out to the stack
area pointed by R15. In case of repeat control instruction (SETRC, LDRS, LDRE), and SR,
RS, and RE load instructions, they cannot be described in positions other than the repeat
module. If described, proper operation cannot be secured.
instr5;
instr6;
Position
Any
Any
Position
instr3
instr4
instr5
Any
Address Pushed Out
RptStart
Program address of illegal instruction
Address Pushed Out
Program address of illegal instruction
RptStart-4
RptStart-2
Program address of illegal instruction

Related parts for HD64F7044F28V