Z8F0413SH005EC Zilog, Z8F0413SH005EC Datasheet - Page 94

IC ENCORE MCU FLASH 4K 20SOIC

Z8F0413SH005EC

Manufacturer Part Number
Z8F0413SH005EC
Description
IC ENCORE MCU FLASH 4K 20SOIC
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheets

Specifications of Z8F0413SH005EC

Core Processor
Z8
Core Size
8-Bit
Speed
5MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
20-SOIC (7.5mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Data Converters
-
Other names
269-3486
PS024314-0308
ONE-SHOT Mode
CONTINUOUS Mode
COUNTER Mode
PWM SINGLE OUTPUT Mode
CAPTURE Mode
COMPARE Mode
GATED Mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
If the timer is enabled the Timer Output signal is complemented after timer reload.
0 = Count occurs on the rising edge of the Timer Input signal
1 = Count occurs on the falling edge of the Timer Input signal
0 = Timer Output is forced Low (0) when the timer is disabled. When enabled, the
Timer Output is forced High (1) upon PWM count match and forced Low (0) upon
Reload.
1 = Timer Output is forced High (1) when the timer is disabled. When enabled, the
Timer Output is forced Low (0) upon PWM count match and forced High (1) upon
Reload.
0 = Count is captured on the rising edge of the Timer Input signal
1 = Count is captured on the falling edge of the Timer Input signal
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
0 = Timer counts when the Timer Input signal is High (1) and interrupts are generated
on the falling edge of the Timer Input.
1 = Timer counts when the Timer Input signal is Low (0) and interrupts are generated
on the rising edge of the Timer Input.
Z8 Encore! XP
Product Specification
®
F0823 Series
Timers
84