W67-X2Q50-5

Manufacturer Part Number
W67-X2Q50-5
Description
CIRCUIT BREAKER SWITCH 5A WH
Manufacturer
Tyco Electronics
Series
W67r
Datasheets

Specifications of W67-X2Q50-5

Breaker Type
Hydraulic-Magnetic
Voltage
65VDC
Current - Trip (it)
5A
Number Of Poles
1
Actuator Type
Toggle
Mounting Type
Panel Mount
No. Of Poles
1
Current Rating
5A
Interrupting Capacity
2kA
Dielectric Strength
1.1kV
Trip Time
0.03s
Voltage Rating Vdc
65V
Trip Time Max
0.03sec
Product Type
Circuit Breakers
Voltage Rating
65 VoltsDC
Mounting Style
Panel
Termination Style
Quick Connect
Circuit Function
Series Trip
Color
White
Features
Several delay curve options, Trip-free operation
Height
50.8 mm
Illuminated
No
Length
51.89 mm
Product
Magnetic Circuit Breaker
Width
19.05 mm
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Other names
7-1393252-9
Catalog 1308242
Issued 3-03 (PDF Rev. 03-10)
W6/W9
series

Related parts for W67-X2Q50-5

W67-X2Q50-5 Summary of contents

Page 1

Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) W6/W9 series ...

Page 2

DC & 50/60 Hz. 400 Hz. CURVE 0 INSTANTANEOUS 10,000 TRIP TIMES OVERLOAD @ 50/ & 400 Hz. 1000 125% 100 ms max. May Trip 150 max. 100 ms max. 100 200 ...

Page 3

Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) ...

Page 4

Catalog 1308242 Issued 3-03 (PDF Rev. 03-10) ...

Page 5

ON LINE A 29° 1.520 30° (38.61) OFF B LOAD Ø .590 (15.00) .750 1.500 (19.05) (38.10) 1.660 2.000 (42.16) (50.80) 1.05 1.22 (26.67) (31.00) 6.32 TH'D. .14 (3.56) DP ...

Page 6

INSIDE (15.88) .03 (.76) .313 (7.95) .47 (11.94) .95 .17 (24.1) (4.32) .08 .625 (2.03) (15.88) 2.00 (50.8) 1.66 (42.16 .27 DIA. (6.86) . .16 DIA. (13.46) (4.06) 1.769 .774 .240 (44.93) (19.65) (6.10) .392 ...

Page 7

LINE ON 29° 1.940 (49.28) 30° OFF LOAD #10-32 .14 STUD (3.56) TERMINATION 2.10 (53.34) 2.50 .74 (64.00) (18.8) .281 2.46 'A' STYLE (7 .14) (62.48) ...