Datasheet
Auxiliary Switch Ratings Table 2
Agency Approvals
UL:
CSA: Accepted as a Supplementary Protector. File LR15734.
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to confirm the product meets the
requirements for a given application.
Issued 11-08
www.tycoelectronics.com
Electrical Data
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.
Dielectric Strength: 50/60 Hz., 1500V: DC, 1100V.
Insulation Resistance: 100 Megohms at 500VDC.
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Relay Trip Coil: (Ratings applicable to all W6 models with this option)
Approvals and Ratings Table 1
W6 Series
W9 Series
UL/CSA
Features
• Designed for the international market. UL Recognized (UL1077 and
• Ratings to 50 amps.
• Heavy duty #10-32 stud connections. (W9)
• Quick-connect or screw terminals. (W6)
• Optional 10 amp auxiliary switch.
• Several delay curve options.
• Choice of toggle or rocker actuator per pole or per unit (W6).
• Optional relay/remote trip pole available.
• Trip-free operation.
Calibration: Breakers will hold 100% of rated current.
UL1500), CSA Accepted and VDE approved.
Maximum
Maximum
Voltage
277/480
Voltage
277/480
Number
Switch
277
277
277
65
65
Recognized as Supplementary Protector under UL 1077. Available
models meet Ignition Protection requirements in accordance with
UL1500. File E69543.
License No. 73782.
A
Units tested at six cycles per minute, 1 second on and 9
seconds off at 25°C ambient.
Breakers may trip between 101% and 124% of rated load
(134% for AC/DC units).
Breakers must trip at 125% of rated load and above (135%
for AC/DC units).
24 to 277VAC, 150mA minimum available current;
6 to 48VDC, 300mA minimum available current.
Frequency
Frequency
50/60
50/60
50/60
50/60 Hz.
(Hz)
50/60
50/60
DC
Voltage
(Hz)
DC
UL1077/CSA (All Circuit Functions)
UL1077/CSA (All Circuit Functions)
125
Dimensions are in inches over
(millimeters) unless otherwise
specified.
3Ø-Wye
3Ø-Wye
Phase
Phase
1
1
-
1
-
Current
(Amps)
10
Current
(Amps)
0.2 - 50
0.2 - 20
0.2 - 20
Current
Rating
21 - 50
(Amps)
0.2 - 50
0.2 - 50
0.2 - 20
Rating
.093 x .020 x .250
(2.36 x .51 x 6.40)
Terminals
WxTxL
Dimensions are shown for reference
purposes only. Specifications and
availability subject to change.
Interrupting
Interrupting
Capacity
(Amps)
Capacity
(Amps)
2,000
5,000
2,500
5,000
2,000
5,000
5,000
Issued 3-03 (PDF Rev. 11-08)
Catalog 1308242
W6 or W9 Series
W6 or W9 Series
Maximum
Typical Resistance and Impedance
Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%.
Mechanical/Environmental Data
Operating Temperature: -40°C to +85°C.
Humidity: Meets requirements of Mil-STD-202 method 103.
Shock: Tested per Mil-STD-202, method 213, test condition C
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06"
Fungus And Moisture Resistance: Special moisture resistant finish
Marking: W6 units have ON and OFF molded on the rocker of rocker
Mounting: Units are mounted with two #6-32 screws from the front of
Weight: Approximately 2.5 ounces per pole.
Voltage
125/250
Maximum
W6/W9
Magnetic Hydraulic
P&B Circuit Breakers
Voltage
415/240
250
48
250
250
65
(100g @ 6 ms).
Current
(Amps)
10.0
20.0
30.0
40.0
50.0
(1.52mm) total excursion in 2 planes.
actuated units (rocker actuated VDE units have international
“1” and “0”). W9 units have ON and OFF molded into the area
at the base of the toggle. International “1” and “0” symbols are
marked on the toggle for both W6 and W9.
0.2
1.0
2.0
5.0
the panel. Metric models for use with M3 x 0.5 screws are
available. To maintain published performance specifications,
units should not be mounted more than 90° from their normal
upright position.
Frequency
Frequency
50/60
50/60
50/60
50/60
50/60
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
(Hz)
(Hz)
DC
DC
UL1500 (Circuit Function X)
VDE (Circuit Function X)
series
3Ø-Wye
Phase
Phase
Resistance
1
1
-
1
-
(Ohms)
90
DC
1.2
0.28
0.04
0.013
0.004
0.0027
0.002
0.0015
applied to all ferrous parts.
Plastic parts are made of inherently
fungus resistant material.
Current
(Amps)
Current
(Amps)
0.2 - 50
0.2 - 50
0.2 - 50
Rating
Rating
0.2-50
0.2-30
0.2-30
31-50
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080208
Impedance
50/60 Hz.
Interrupting
(Ohms)
Interrupting
90
Capacity
1.2
0.28
0.04
0.013
0.005
0.004
0.002
0.0015
Capacity
(Amps)
(Amps)
3,000
1,000
1,000
2,000
5,000
2,000
5,000
1

Related parts for W67-X2Q12-0.50

W67-X2Q12-0.50 Summary of contents

Page 1

Features • Designed for the international market. UL Recognized (UL1077 and UL1500), CSA Accepted and VDE approved. • Ratings to 50 amps. • Heavy duty #10-32 stud connections. (W9) • Quick-connect or screw terminals. (W6) • Optional 10 amp auxiliary ...

Page 2

Time vs. Current Trip Curves For W6 Series and W9 Series AC 50/60 Hz. DC & 50/60 Hz. 400 Hz. CURVE 0 INSTANTANEOUS 10,000 TRIP TIMES OVERLOAD @ 50/ & 400 Hz. 1000 125% 100 ms ...

Page 3

... Four pole 9 = Red toggle ) 4.0 6.0 7.5 9.0 11.0 15.0 5.0 7.0 8.0 10.0 12.0 20.0 W67-X2Q13-25 W67-X2Q52-15 W67-X2Q13-30 W67-X2Q52-20 W67-X2Q50-5 W67-X2Q52-30 W67-X2Q50-10 W67-X2Q110-15 W67-X2Q52-5 W67-X2Q110-20 W67-X2Q52-10 W68-X2Q12-3 Dimensions are shown for reference purposes only. Specifications and availability subject to change 25.0 35 ...

Page 4

Ordering Information W9 Series 1. Circuit Breaker Mounting #6-32 mounting threads M3.0 x 0.5 mounting threads. 2. Number of Poles Single pole 92 = Two pole 3. Circuit Function: (Only X is VDE approved) ...

Page 5

Outline Dimensions - Toggle Actuator Models W6 Series 2.043 .66 (51.89) (16.8) .235 1.640 (5.97) (41.66) .245 (6.22 LINE 29° 1.520 30° (38.61) OFF B LOAD W6 Series – One Actuator Per Pole 1 Pole 2 Pole Ø ...

Page 6

... Dimensions are shown for reference purposes only. Specifications and availability subject to change R1.0 .78 (25.4) (19.8) .17 REF. (4.32) .44 84-004 toggle guard shown (11.18) with W67 series circuit .20 breaker mounted in a panel. (5.08 & 4 Pole Actuator Per Pole 3.000 (76.20) 4 2.250 POLE (57 .15) 3 1.500 POLE (38 ...

Page 7

... LINE C 1.940 NO (49.28) NC LOAD 2.50 (64.00) © 2008 by Tyco Electronics Corporation. All Rights Reserved. P&B, TE logo and Tyco Electronics are trademarks. Issued 11-08 Dimensions are in inches over www.tycoelectronics.com (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 11-08) Series Trip Model ...