LM95213EB/NOPB National Semiconductor, LM95213EB/NOPB Datasheet - Page 17

no-image

LM95213EB/NOPB

Manufacturer Part Number
LM95213EB/NOPB
Description
BOARD EVALUATION FOR LM95213
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheets

Specifications of LM95213EB/NOPB

Sensor Type
Temperature
Sensing Range
-40°C ~ 140°C
Interface
SMBus (2-Wire/I²C)
Sensitivity
±1°C
Voltage - Supply
3 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
LM95213
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM95213EB
Register Name
Local Temp MSB
Local Temp LSB
Remote Temp 1 MSB – Signed
Remote Temp 1 LSB – Signed,
Digital Filter Off
Remote Temp 1 LSB – Signed,
Digital Filter On
Remote Temp 2 MSB – Signed
Remote Temp 2 LSB – Signed,
Digital Filter Off
Remote Temp 2 LSB – Signed,
Digital Filter On
Remote Temp 1 MSB – Unsigned
Remote Temp 1 LSB – Unsigned,
Digital Filter Off
Remote Temp 1 LSB – Unsigned,
Digital Filter On
Remote Temp 2 MSB – Unsigned
Remote Temp 2 LSB – Unsigned,
Digital Filter Off
Remote Temp 2 LSB – Unsigned,
Digital Filter On
Remote 1 Offset
Remote 2 Offset
Configuration
Conversion Rate
Channel Conversion Enable
Filter Setting
1-shot
2.
1.13 ONE-SHOT CONVERSION
The One-Shot register is used to initiate a round of conver-
sions and comparisons when the device is in standby mode,
2.0 LM95213 Registers
Command register selects which registers will be read from or written to. Data for this register should be transmitted during the
Command Byte of the SMBus write communication.
P0-P7: Command
Register Summary
insure a timeout of all devices on the bus the SMBCLK
or SMBDAT lines must be held low for at least 35ms.
When SMBDAT is HIGH, have the master initiate an
SMBus start. The LM95213 will respond properly to an
SMBus start condition at any point during the
communication. After the start the LM95213 will expect
an SMBus Address address byte.
Command
P7
(Hex)
0x1A
0x2A
Byte
0x10
0x20
0x11
0x21
0x12
0x22
0x19
0x29
0x31
0x32
0x03
0x04
0x05
0x06
0x0F
P6
Read/
Write
R/W
R/W
R/W
R/W
R/W
R/W
WO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
P5
Command Byte
SIGN
SIGN
SIGN
SIGN
SIGN
128
128
1/2
1/2
1/2
1/2
1/2
D7
P4
17
STBY
1/4
1/4
1/4
1/4
1/4
D6
64
64
64
64
64
32
32
P3
after which the device returns to standby. This is not a data
register and it is the write operation that causes the one-shot
conversion. The data written to this address is irrelevant and
is not stored. A zero will always be read from this register. All
the channels that are enabled in the Channel Enable Register
will be converted once and the TCRIT1, TCRIT2 and
TCRIT3 pins will reflect the comparison results based on this
round of conversion results of the channels that are not
masked.
1/8
1/8
1/8
1/8
1/8
D5
32
32
32
32
32
16
16
P2
1/16
1/16
1/16
1/16
D4
16
16
16
16
16
P1
0
0
0
0
0
8
8
R2F1
1/32
1/32
1/32
1/32
D3
P0
8
0
8
0
8
0
8
0
8
0
4
4
R2CE
R2F0
D2
4
0
4
0
4
0
4
0
4
0
2
2
R1CE
R1F1
CR1
D1
2
0
2
0
2
0
2
0
2
0
1
1
R1F0
CR0
LCE
D0
1/2
1/2
1
0
1
0
1
0
1
0
1
0
www.national.com
Default
(Hex)
POR
0x00
0x00
0x00
0x02
0x1F
0x0F