MAX1282EVC16 Maxim Integrated Products, MAX1282EVC16 Datasheet - Page 5

no-image

MAX1282EVC16

Manufacturer Part Number
MAX1282EVC16
Description
EVAL KIT FOR MAX1282
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX1282EVC16

Number Of Adc's
1
Number Of Bits
12
Sampling Rate (per Second)
400k
Data Interface
Serial
Inputs Per Adc
4 Single Ended
Input Range
±VREF/2
Power (typ) @ Conditions
13.75mW @ 400kSPS
Voltage Supply Source
Single Supply
Operating Temperature
0°C ~ 70°C
Utilized Ic / Part
MAX1282
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ELECTRICAL CHARACTERISTICS—MAX1283 (continued)
(V
+2.5V at REF, REFADJ = V
CONVERSION RATE
ANALOG INPUTS (CH3–CH0, COM)
INTERNAL REFERENCE
EXTERNAL REFERENCE (reference buffer disabled, reference applied to REF)
DIGITAL INPUTS (DIN, SCLK, CS, SHDN)
Conversion Time (Note 5)
Track/Hold Acquisition Time
Aperture Delay
Aperture Jitter
Serial Clock Frequency
Duty Cycle
Input Voltage Range, Single
Ended and Differential (Note 6)
Multiplexer Leakage Current
Input Capacitance
REF Output Voltage
REF Short-Circuit Current
REF Output Temperature
Coefficient
Load Regulation (Note 7)
Capacitive Bypass at REF
Capacitive Bypass at REFADJ
REFADJ Output Voltage
REFADJ Input Range
REFADJ Buffer Disable
Threshold
Buffer Voltage Gain
Buffer Voltage Gain
REF Input Voltage Range
REF Input Current
Input High Voltage
Input Low Voltage
Input Hysteresis
Input Leakage
Input Capacitance
DD1
= V
PARAMETER
DD2
= +2.7V to +3.6V, COM = GND, f
300ksps/400ksps, Single-Supply, 4-Channel,
Serial 12-Bit ADCs with Internal Reference
_______________________________________________________________________________________
DD1
, T
A
= T
SYMBOL
TC V
t
V
f
CONV
V
V
t
V
SCLK
V
MIN
ACQ
HYST
C
CH_
I
REF
INH
INL
IN
IN
REF
to T
MAX
Normal operating mode
Normal operating mode
Normal operating mode
Unipolar, V
Bipolar, V
referenced to COM or CH_
On/off leakage current, V
T
0 to 0.75mA output load
For small adjustments, from 1.22V
To power down the internal reference
(Note 8)
V
V
In full power-down mode, f
V
A
REF
REF
IN
, unless otherwise noted. Typical values are at T
= +25°C
OSC
= 0 or V
= 2.500V, f
= 2.500V, f
= 4.8MHz, 50% duty cycle, 16 clocks/conversion cycle (300ksps), external
COM
COM
DD2
or V
CONDITIONS
= 0
SCLK
SCLK
CH_
= f
= 0
= V
MAX
CH_
REF
SCLK
= 0 or V
/2,
= 0
DD1
2.480
0.01
MIN
A
3.3
0.5
4.7
1.4
1.0
2.0
40
= +25°C.)
±0.001
2.500
±100
TYP
1.22
2.05
2.05
<50
±15
200
18
0.1
0.2
10
15
15
V
±V
DD1
V
2.520
50mV
V
DD1
350
320
2.0
0.8
±1
±1
REF
10
10
REF
MAX
5
625
4.8
60
- 1.0
+
/2
ppm/°C
mV/mA
UNITS
MHz
mA
V/V
V/V
mV
µA
µA
µA
µs
ns
ns
ps
pF
µF
µF
pF
%
V
V
V
V
V
V
V
V
5

Related parts for MAX1282EVC16