DS26528DK Maxim Integrated Products, DS26528DK Datasheet - Page 82

no-image

DS26528DK

Manufacturer Part Number
DS26528DK
Description
KIT DESIGN FOR DS26528
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS26528DK

Main Purpose
Telecom, Framer and Line Interface Units (LIUs)
Utilized Ic / Part
G575DS26528
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
8.11.3.5
For short-haul mode, loss is declared if the received signal level is 3dB lower from the programmed value (based
on
declared at 15dB. LOS is reset if the following criteria are met:
For long-haul mode, loss is detected if the received signal level is 3dB lower from the programmed value (based on
Table
will be 33dB. LOS is reset if the following criteria are met:
8.11.3.6
For short-haul mode, loss is declared if the received signal level is 3dB lower from the programmed value (based
on
declared at 15dB. LOS is reset if the receive signal level is greater than or equal to the programmed sensitivity
level for a duration of 192-bit periods.
For long-haul mode, loss is detected if the received signal level is 3dB lower from the programmed value (based on
Table
will be 33dB. LOS is reset if the receive signal level is greater than or equal to the programmed sensitivity level for
a duration of 192-bit periods.
8.11.3.7
For short-haul mode, loss is declared if the received signal level is 3dB lower from the programmed value (based
on
or equal to programmed sensitivity level for a duration of 192-bit periods.
For long-haul mode, loss is declared if the received signal level is 3dB lower from the programmed value (based on
Table
equal to the programmed sensitivity level for a duration of 192-bit periods.
Table
Table
Table
1) 24 or more ones are detected in 192-bit period with a programmed sensitivity level measured at RTIP and
2) During the 192 bits, fewer than 100 consecutive zeros are detected.
1) 24 or more ones are detected in 192-bit period with a programmed sensitivity level measured at RTIP and
2) During the 192 bits, fewer than 100 consecutive zeros are detected.
9-19) for a duration of 192-bit periods. Hence, if the sensitivity is programmed at 30dB, loss declaration level
9-19) for a duration of 192-bit periods. Hence, if the sensitivity is programmed at 30dB, loss declaration level
9-19) continuous duration of 2048-bit periods (1ms). LOS is reset if the receive signal level is greater than or
RRING.
RRING.
9-19) continuous duration of 2048-bit periods (1ms). LOS is reset if the receive signal level is greater than
9-19) for a duration of 192-bit periods. Hence, if the sensitivity is programmed to be 12dB, loss will be
9-19) for a duration of 192-bit periods. Hence, if the sensitivity is programmed to be 12dB, loss will be
ANSI T1.231 for T1 and J1 Modes
ITU-T G.775 for E1 Modes
ETS 200 233 for E1 Modes