VPOL15A-5-SIP CUI Inc, VPOL15A-5-SIP Datasheet - Page 5

CONVERTER DC/DC 3.63VOUT 15A SIP

VPOL15A-5-SIP

Manufacturer Part Number
VPOL15A-5-SIP
Description
CONVERTER DC/DC 3.63VOUT 15A SIP
Manufacturer
CUI Inc
Series
V-Infinity VPOL15Ar
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of VPOL15A-5-SIP

Output
0.9 ~ 3.63V
Number Of Outputs
1
Power (watts)
54W
Mounting Type
Through Hole
Voltage - Input
3 ~ 5.5V
Package / Case
11-SIP Module (10 Leads)
1st Output
3.63 VDC @ 15A
Size / Dimension
2.00" L x 0.34" W x 0.50" H (50.8mm x 8.6mm x 12.7mm)
Power (watts) - Rated
54W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
cUL, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
Other names
102-1291
PART NUMBER: VPOL15A-5-SIP
5. Main Features and Functions
5.1 Operating Temperature Range
V-Infinity’s VPOL15A-5-SIP series converters highly efficient converter
design has resulted in its ability to operate over a wide ambient
temperature environment ( -40° C to 85°C). Due consideration must be
given to the de-rating curves when ascertaining maximum power
be drawn from the converter. The maximum power drawn is influenced
by a number of factors, such as:
5.2 Over-Temperature Protection (OTP)
The VPOL15A-5-SIP series converters are equipped with non-latching
over-temperature protection. A te mperature sensor monitors the
temperature of the hot spot (typically, top switch). If the temperature
exceeds a threshold of 120°C (typical) the converter will shut down,
disabling the output. When the temperature has decreased the
will automatically restart.
The over-temperature condition can be induced by a variety of
such as external overload condition or a system fan failure.
5.3 Output Voltage Adjustment
Section 7.9 describes in detail as to how to trim the output voltage
respect to its set point. The output voltage on all models is trimmable in
the range 0.9 – 3.63Vdc.
5.4 Safe Operating Area (SOA)
Figure 2 provides a graphical representation of the safe operating
(SOA) of the converter. This representation assumes ambient operating
conditions such as airflow are met as per thermal guidelines provided in
Sections 7.2 and 7.3.
5.5 Over Current Protection
All different voltage models have a full continuous
The unit will auto recover once the short circuit is removed. To provide
protection in a fault condition, the unit is equipped with internal over-
20050 SW 112
Figure 2. Maximum Output Current Safe
These can be effective heat sinks for the converter.
Input voltage range.
Output load current.
Air velocity (forced or natural convection).
Mounting orientation of converter PCB with respect to the
Motherboard PCB design, especially ground and power planes.
Vo,nom
Vo
Safe Operating Area
th
Ave. Tualatin, Oregon 97062
CURRENT (A)
Io,max
short-circuit protection.
Operating Area
Io,CL
reasons
Io
airflow.
converter
that can
area
with
phone 503.612.2300 fax 503.612.2382
DESCRIPTION: point of load converter
current protection. The unit operates normally once the fault condition is
removed. The power module
the event of an over current
protection.
5.6 Remote On/Off
The remote on/off input feature
to turn the converter on
standard. The VPOL15A-5-SIP series converters are turned on if the
remote on/off pin is high, or left open or floating. Setting the pin low will
turn the converter ‘Off’. The signal level of the remote on/off input is
defined with respect to ground. If not using the remote on/off pin, leave
the pin open (module will be on). The part number suffix “N” is Negative
remote on/off version. The unit is guaranteed off over the full temperature
range if this voltage level exceeds 2.8Vdc. The converters are turned on
If the on/off pin input is low or left open. The recommended VPOL15A-5-
SIP remote on/off drive circuit is shown as figure 3, 4.
or off. Active-high remote on/off is available as
converter will go into a hiccup mode
will supply up to 150% of rated current. In
of the converter allows external circuitry
rev.
page
date
08/2007
5 of 12

Related parts for VPOL15A-5-SIP