NHD-10032AZ-FSY-GBW Newhaven Display, NHD-10032AZ-FSY-GBW Datasheet - Page 12

LCD MOD GRAPH 100X32 Y/G TRANSFL

NHD-10032AZ-FSY-GBW

Manufacturer Part Number
NHD-10032AZ-FSY-GBW
Description
LCD MOD GRAPH 100X32 Y/G TRANSFL
Manufacturer
Newhaven Display
Series
NHD-10032AZ-Fr
Datasheet

Specifications of NHD-10032AZ-FSY-GBW

Display Type
LCD - Monochrome
Display Mode
Transflective
Viewing Area
46.00mm L x 18.40mm W
Backlight
LED - Yellow/Green
Dot Size
0.38mm W x 0.43mm H
Dot Pitch
0.43mm x 0.48mm
Dot Pixels
100 x 32
Pixel Density
100 x 32
Fluid Type
STN
Module Size (w X H X T)
65 mm x 28.4 mm x 8 mm
Backlighting
LED Yellow / Green
Background Color
Gray
Operating Temperature Range
- 20 C to + 70 C
Style
LCD Graphic Display
Interface
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
NHD-10032AZ
Newhaven Display International, LLC
Select duty (A8H; A9H)
This command sets the duty cycle of the LCD drive and is only valid for the SED1520F and
SED1522F.it is invalid for the SED1521F, which performs passive operation. The duty cycle of
the SED1521F is determined by the externally generated FR signal.
SED1520
D=: 1/32 duty cycle 1/16 duty cycle
D=: 1/16 duty cycle
When using the SED1520F0A, SED1522F0A (having a built-in oscillator) and the SED1521F0A
continuously, set the duty as follows:
READ-MODIFY-WRITE (E0H)
This command defeats column address register auto -increment after data reads. The current
contents of the column address register are saved. This mode remains active until an end
command is repeated.
Operation sequence during cursor display
When the end command is entered, the column address is returned to the one used during input
of read-modify-write command. This function can reduce the load of MPU when data change is
repeated at a specific
Display area (such as cursor blinking).
*Any command other than data read or write can be used in the read-modify-write mode.
However, the column address set command cannot be used.
A0
0
A0
0
E (RD) R/W (/WR)
1
E (RD) R/W (/WR)
1
SED1522
1/8 duty cycle
0
SED1520FOA
SED1522FOA
0
1
D7
D7
1
1/32
1/16
1/116
1/8
0
D6
D6
1
1
D5
D5
1
SED1521FOA
1/32
1/16
1/32
1/16
0
D4
D4
0
1
D3
D3
0
0
D2
D2
0
0
D1
D1
0
Page 12 of 14
D
D0
D0
0

Related parts for NHD-10032AZ-FSY-GBW