ADT7310TRZ Analog Devices Inc, ADT7310TRZ Datasheet - Page 16

IC TEMP SENSOR 16BIT SPI 8SOIC

ADT7310TRZ

Manufacturer Part Number
ADT7310TRZ
Description
IC TEMP SENSOR 16BIT SPI 8SOIC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADT7310TRZ

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Oscillator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 150°C
Output Type
SPI™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Ic Output Type
Digital
Sensing Accuracy Range
± 0.5°C
Supply Current
230µA
Supply Voltage Range
2.7V To 5.5V
Resolution (bits)
16bit
Sensor Case Style
SOIC
No. Of Pins
8
Temperature Sensor Function
Temp Sensor
Package Type
SOIC N
Operating Temperature (max)
150C
Operating Temperature Classification
Military
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (max)
5.5V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7310TRZ
Manufacturer:
ADI
Quantity:
1
Part Number:
ADT7310TRZ-REEL7
Manufacturer:
AD
Quantity:
2 100
ADT7310
TEMPERATURE VALUE REGISTER
The temperature value register stores the temperature measured
by the internal temperature sensor. The temperature is stored as
a 16-bit twos complement format. The temperature is read back
from the temperature value register (Register Address 0x02) as a
16-bit value.
Bit 2, Bit 1, and Bit 0 are event alarm flags for T
T
to a 16-bit digital value, Bit 2, Bit 1, and Bit 0 are no longer used
as flag bits and are, instead, used as the LSB bits for the extended
digital value.
Table 9. Temperature Value Register (Register Address 0x02)
Bit
[0]
[1]
[2]
[3:7]
[8:14]
[15]
Table 10. ID Register (Register Address 0x03)
Bit
[2:0]
[7:3]
Table 11. T
Bit
[15:0]
LOW
. When the ADC is configured to convert the temperature
CRIT
Default Value
0
0
0
00000
0000000
0
Default Value
XXX
11000
Default Value
0x4980
Setpoint Register (Register Address 0x04)
Type
R
R
R
R
R
R
Type
R
R
Type
R/W
Name
T
T
T
Temp
Temp
Sign
Name
Revision ID
Manufacture ID
Name
T
LOW
HIGH
CRIT
CRIT
CRIT
flag/LSB2
flag/LSB0
flag/LSB1
, T
HIGH
, and
Description
16-bit critical overtemperature limit, stored in twos complement format.
Temperature value in twos complement format.
Sign bit, indicates if the temperature value is negative or positive.
Description
Flags a T
(13-bit resolution). When the temperature value is below T
Contains the Least Significant Bit 0 of the 15-bit temperature value if the
configuration register, Register Address 0x01[7] = 1 (16-bit resolution).
Flags a T
(13-bit resolution). When the temperature value is above T
Contains the Least Significant Bit 1 of the 15-bit temperature value if the
configuration register, Register Address 0x01[7] = 1 (16-bit resolution).
Flags a T
(13-bit resolution). When the temperature value exceeds T
Contains the Least Significant Bit 2 of the 15-bit temperature value if the
configuration register, Register Address 0x01[7] = 1 (16-bit resolution).
Temperature value in twos complement format.
Contains the silicon revision identification number.
Contains the manufacturer identification number.
Description
Rev. 0 | Page 16 of 24
LOW
HIGH
CRIT
event if the configuration register, Register Address 0x01[7] = 0
event if the configuration register, Register Address 0x01[7] = 0
event if the configuration register, Register Address 0x01[7] = 0
ID REGISTER
This 8-bit read-only register stores the manufacturer ID in Bit 7
to Bit 3 and the silicon revision in Bit 2 to Bit 0.
T
The 16-bit T
stores the critical overtemperature limit value. A critical
overtemperature event occurs when the temperature value
stored in the temperature value register exceeds the value
stored in this register. The CT pin is activated if a critical
overtemperature event occurs. The temperature is stored in
twos complement format with the MSB being the temperature
sign bit.
The default setting for the T
CRIT
SETPOINT REGISTER
CRIT
setpoint register (Register Address 0x04)
CRIT
setpoint is 147°C.
CRIT
HIGH
LOW,
, this bit it set to 1.
, this bit it set to 1.
, this bit it set to 1.

Related parts for ADT7310TRZ