TLE8102SG Infineon Technologies, TLE8102SG Datasheet - Page 13

no-image

TLE8102SG

Manufacturer Part Number
TLE8102SG
Description
IC SWITCH LOSIDE 2CH DSO-12
Manufacturer
Infineon Technologies
Type
Low Sider
Datasheet

Specifications of TLE8102SG

Input Type
SPI
Number Of Outputs
2
On-state Resistance
180 mOhm
Current - Peak Output
6.5A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-12
Packages
PG-DSO-12
Thermal Class
Heatslug down
Id Nom
2 x 2 A
Pin Count
12.0 Pins
Channels
2.0
Comment
high current loads with sensing (e.g. O2)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output / Channel
-
Other names
SP000308142
TLE8102SG
TLE8102SGTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE8102SG
Manufacturer:
INFINEON
Quantity:
2 188
Part Number:
TLE8102SG
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
TLE8102SG
Quantity:
4 800
Company:
Part Number:
TLE8102SG
Quantity:
98
Figure 10
5.3.3.2
A dedicated temperature sensor for each channel detects if the temperature of its channel exceeds the over
temperature shutdown threshold. If the channel temperature exceeds the over temperature shutdown threshold,
the overheated channel is switched off immediately to prevent destruction. At the same time (no delay), the over
temperature flag Tn is set. If the status outputs are used for diagnosis, the over temperature flag is cleared
immediately after the over temperature condition is no longer present. If using the SPI interface and fault pin for
diagnosis, the over temperature flag of the affected channel is cleared by the rising edge of the
successful SPI transmission.
The restart response of the channel can be programmed via SPI. If automatic autorestart is selected, after cooling
down, the channel is switched on again with thermal hysteresis T
remains switched off even after cooling down. The channel can be restarted only if first turned off with either the
parallel input or SPI. In addition, the channel must first be turned off before the the over temperature flag of the
affected channel can be cleared by the rising edge of the
For timing information, please refer to
Data Sheet
OV L
OV L
IN
IN
I
I
V
V
ST
ST
FAULT
FAULT
SO
SO
CS
CS
OUT
OUT
O UT
O UT
I
I
V
V
(Norm al Function)
(Norm al Function)
D(lim 2)
D(lim 2)
Bat
Bat
I
I
nom
nom
I*R
I*R
H H
H H
Over Load Behavior - Latched Shutdown (current limit 2)
Over Temperature Protection
ON
ON
O N
O N
t
t
d(off)
d(off)
set
set
ILIM 2 Failure
ILIM 2 Failure
latched
latched
shutdown
shutdown
set
set
set
set
(O VL)
(O VL)
HL
HL
reset
reset
OFF
OFF
Figure 11
reset
reset
reset
reset
V alid SP I cycles
V alid SP I cycles
H H
H H
t
t
d(off)
d(off)
and
OVL
OVL
Condition
Condition
ILIM2 Failure
ILIM2 Failure
latched
latched
shutdown
shutdown
Figure 12
13
CS
signal after a successful SPI transmission.
Electrical and Functional Description of Blocks
Smart Dual Channel Powertrain Switch
HL
HL
for details.
j
. If latching shutdown is selected, the channel
H H
H H
t
t
d(off)
d(off)
ILIM 2 Failure
ILIM 2 Failure
latched
latched
shutdown
shutdown
V1.4, 2008-05-08
CS
OL_CurrLim2.vsd
H L
H L
TLE8102SG
signal after a
HH
HH