BTS5682E Infineon Technologies, BTS5682E Datasheet - Page 29

no-image

BTS5682E

Manufacturer Part Number
BTS5682E
Description
IC LED DRIVER DSO-36
Manufacturer
Infineon Technologies
Datasheets

Specifications of BTS5682E

Topology
PWM, Switched Capacitor (Charge Pump)
Number Of Outputs
6
Internal Driver
Yes
Type - Primary
Automotive
Frequency
2MHz
Voltage - Supply
3.8 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
DSO-36
Internal Switch(s)
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Output
-
Operating Temperature
-
Current - Output / Channel
-
Efficiency
-
Lead Free Status / Rohs Status
 Details
Other names
SP000296428

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS5682E
Quantity:
16
For diagnosis feedback at different operation modes, please see
Table 1
Operation Mode
Normal Operation (OFF)
Short Circuit to GND
Thermal shut down
Short Circuit to
Open Load
Normal Operation (ON)
Current Limitation
Short Circuit to GND
Dynamic Temperature Sensor shut down
Thermal shut down
Short Circuit to
Open Load
1) L = low level, H = high level, Z = high impedance, potential depends on leakage currents and external circuit.
2) The error flags are latched until they are transmitted in the standard diagnosis word via SPI.
3) The over temperature flag is set latched (in OFF states also) and can be cleared by SPI command HWCR.CTL.
8.1
The standard diagnosis at the SPI interface provides information about each channel. The error flags, an OR
combination of the over temperature flags and the over load monitoring signals are provided in the SPI standard
diagnosis bits ERRn.
The over load monitoring signals are latched in the error flags and cleared each time the standard diagnosis is
transmitted via SPI. In detail, they are cleared between the second and third raising edge of the SCLK signal.
The over temperature flags, which cause an overheated channel to latch off, are latched directly at the gate control
block. The latches are cleared by SPI command HWCR.CTL.
Please note: The over temperature information is latched twice. When transmitting a clear thermal latch command
(HWCR.CTL), the error flag is cleared during command transmission of the next SPI frame and ready for latching
after the third raising edge of the SCLK signal. As a result, the first standard diagnosis information after a CTL
command will indicate a failure mode at the previously affected channels although the thermal latches have been
cleared already. In case of continuous over load, the error flags are set again immediately because of the over
load monitoring signal.
Data Sheet
x = undefined.
Operation Modes
Diagnosis Word at SPI
V
V
BB
BB
1)
Input Level
OUT.OUTn
L / 0
(OFF-state)
H / 1
(ON-state)
29
Output
Level V
GND
GND
Z
V
Z
~
<
~GND
Z
Z
V
V
V
BB
BB
BB
V
BB
Table
BB
OUT
1.
Current
Sense I
Z
Z
Z
Z
Z
I
Z
Z
Z
Z
< I
Z
L
/ k
L
/ k
ILIS
ILIS
IS
Error Flag
ERRn
0
0
0
0
0
0
1
1
1
1
0
0
SPOC - BTS5682E
3)
3)
Rev. 1.0, 2008-01-22
2)
Diagnosis
DCR.
SBM
1
1
x
0
x
0
x
1
x
x
0
0

Related parts for BTS5682E