VI-ARM-C11 VICOR [Vicor Corporation], VI-ARM-C11 Datasheet - Page 3

no-image

VI-ARM-C11

Manufacturer Part Number
VI-ARM-C11
Description
Autoranging Rectifier Modules Up to 1500 Watts
Manufacturer
VICOR [Vicor Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VI-ARM-C11
Manufacturer:
VICOR
Quantity:
12 000
Part Number:
VI-ARM-C11
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
VI-ARM-C11-U
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
VI-ARM-C11-V
Manufacturer:
VICOR
Quantity:
20 000
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
* Tracking error between BUS OK and Enable thresholds
Electrical Characteristics, continued
Parameter
AC Bus OK (B OK)
Module Enable (EN)
Over voltage shutdown
AC Bus OK - module enable, differential error*
Parameter
MTBF
Baseplate material
Cover
Pin material
Weight
Size
MODULE GENERAL SPECIFICATIONS
MODULE CONTROL SPECIFICATIONS
On-state resistance (low)
On-state current (low)
Off-state voltage
On-state threshold
Off-state threshold
On-state resistance (low)
On-state current (low)
Off-state voltage
On-state threshold
Off-state threshold
Set your site on VICOR at www.vicorpower.com
Min
(57,9 x 36,8 x 12,7)
2.28 x 1.45 x 0.5
14.8
14.8
Min
235
200
235
200
380
15
>1,000,000
2.1 (60)
Typ
15.0
15.0
Typ
240
205
240
205
390
17
Max
Max
15.2
15.2
ARM, Autoranging Rectifier Module
245
210
245
210
400
-50
15
15
50
20
ounces (grams)
inches
hours
(mm)
Unit
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
mA
mA
Notes
25˚C, ground benign
Aluminum
Polyetherimide
Copper, tin/lead solder dipped
Notes
To negative output - bus normal
Bus normal
Bus abnormal, 27K internal pull up to 15Vdc (Fig. 10)
Output bus voltage
Output bus voltage
To negative output - converters are disabled
150K internal pull up to 15Vdc (Fig. 9)
Output bus voltage
Output bus voltage
AC Bus OK and module enable thresholds track
Rev. 2.4
Page 3 of 12