VI-ARM-C11 VICOR [Vicor Corporation], VI-ARM-C11 Datasheet - Page 2

no-image

VI-ARM-C11

Manufacturer Part Number
VI-ARM-C11
Description
Autoranging Rectifier Modules Up to 1500 Watts
Manufacturer
VICOR [Vicor Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VI-ARM-C11
Manufacturer:
VICOR
Quantity:
12 000
Part Number:
VI-ARM-C11
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
VI-ARM-C11-U
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
VI-ARM-C11-V
Manufacturer:
VICOR
Quantity:
20 000
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply
for AC mains having up to 5% total harmonic distortion.
Parameter
Operating input voltage
Operating input voltage
Input undervoltage
Input surge withstand
AC line frequency
AC line frequency
Input current, rms
Input current, rms
Power factor
Inrush current
Holdup capacitance
Parameter
Output power
Output power
Efficiency, 120Vac
Efficiency, 240Vac
Output voltage
Parameter
Agency approvals
Isolation voltage (in to out)
Isolation voltage (I/O to baseplate)
Leakage current
SAFETY SPECIFICATIONS
MODULE INPUT SPECIFICATIONS
MODULE OUTPUT SPECIFICATIONS
Min
Min
180
200
90
47
47
94
96
0
0
0.60
0
0
Set your site on VICOR at www.vicorpower.com
VI-ARM - 1
VI-ARM - 1
Typ Max
Typ Max
96
98
None
1500
Min
1600
132
264
280
880
500
750
375
7.4
5.4
90
63
30
Typ
Min
180
Min
200
90
47
47
94
96
0
0
0.60
0
0
VI-ARM - 2
VI-ARM - 2
Typ Max
Typ Max
Max
100
96
98
ARM, Autoranging Rectifier Module
3300
1000
1500
14.8
10.8
132
264
280
880
375
90
63
60
Volts, rms
Unit
µA
Amps
Amps
Amps
Watts
Watts
Unit
Unit
Vac
Vac
Vac
Vac
Vdc
Hz
Hz
µF
%
%
Notes
Autoranging (doubler mode)
Autoranging (bridge mode)
No damage
100ms
C-Grade
T-Grade
120Vac
240Vac
Typical line voltage condition
264Vac peak line, cold start
Notes
90-132Vac
180-264Vac
90-264Vac
Notes
UL 1950, CSA 22.2 No. 950,
TÜV, VDE, EN60950, CE Marked
Isolation provided by DC-DC converter(s)
No filter
Rev. 2.4
Page 2 of 12

Related parts for VI-ARM-C11