f75334 Feature Integration Technology Inc., f75334 Datasheet - Page 18

no-image

f75334

Manufacturer Part Number
f75334
Description
Performance Controller
Manufacturer
Feature Integration Technology Inc.
Datasheet
Over Temperature Signal (OVT#)
Temperature PME#
exceeds the over-temperature threshold value, OVT# will be asserted until the temperature
goes below the hysteresis temperature.
or going below hysteresis will cause an interrupt if the previous interrupt has been reset by
writing “1” all the interrupt Status Register.
OVT# alert for temperature is shown as figure 7-3. When monitored temperature
PME# interrupt for temperature is shown as figure 7-4. Temperature exceeding high limit
SMI#
(level mode
active low)
*Interrupt Reset when Interrupt Status Registers are written 1
(pulse mode)
T
T HYST
OVT#
To
HYST
To
*
11
*
Fig 7-3
Fig 7-4
*
*
F75334
July, 2007
V0.25P

Related parts for f75334