f75386 Feature Integration Technology Inc., f75386 Datasheet - Page 12

no-image

f75386

Manufacturer Part Number
f75386
Description
Dual ?1o C Accuracy Temperature Sensor Ic With Fan Speed Control
Manufacturer
Feature Integration Technology Inc.
Datasheet
F75386
6.4.3 Alert Response Address mode
command to ask that which device is pulling ALERT# to low. When the ALERT# is pulled to low by F75386 and F75386
receives the ARA command sent by the master, F75386 will send its address to the master. The F75386 will reset its
ALERT# output and set the ALERT Mask bit once the master acknowledges its response of device address. The master may
read F75386’s status registers to check what the triggering conditions occur. At the end of interrupt service routine, the
master has to reset ALERT Mask bit in configuration register. Note that the triggering conditions do not include BUSY and
OPEN status in Configuration Register (index 02h). The ARA, 000 1100, is a general call address and is defined in SMBus
specifications. No devices should be assigned to this address.
If ALERT# is connected to one or more ALERT# outputs of SMBus compatible devices, the master may send an ARA
ALERT Mask
Remote Temperature High Limit
ALERT Mask
Remote Temperature High Limit
F75386 ALERT# pin
F75386 ALERT# pin
Monitoring Remote Temperature
Monitoring Remote Temperature
End of temperature conversion
TIME
ALERT Mask is set and Alert Status is clear
TIME
after reading status register
-8-
ALERT Mask is set after alerting device
address is transmitted correctly
Remote High Alert Status
Alert Status is cleared after reading
status register
Remote High Alert Status
F75386
July,
V0.27P
2007

Related parts for f75386