f75386 Feature Integration Technology Inc., f75386 Datasheet - Page 11

no-image

f75386

Manufacturer Part Number
f75386
Description
Dual ?1o C Accuracy Temperature Sensor Ic With Fan Speed Control
Manufacturer
Feature Integration Technology Inc.
Datasheet
F75386
03h). When pin 6 is used as ALERT# output, there are three different alert functions can be used. The interrupt methods that
ALERT# pin can act are (1) Comparator mode (2) Interrupt mode (3) Alert Response Address mode.
6.4.1 Comparator mode
comparator. If the triggering conditions occur, ALERT# will go to low and relative alert status will be asserted until those
conditions are no longer present. This mode is not the power-on default state. Note that the triggering conditions do not
include BUSY and OPEN status in Configuration Register (index 02h).
6.4.2 Interrupt mode
triggering conditions occur, relative alert status will be asserted and ALERT# will go to low. The F75386 will set the ALERT
Mask bit and relative alert status will be cleared after master’s reading of the Status Register (Index 02h or 18h). The ALERT
Mask bit is set in order to prevent further ALERT# triggering after the end of one temperature conversion if the triggering
conditions are still present. At the end of interrupt service routine, the master has to reset ALERT Mask bit in configuration
register. Note that the triggering conditions do not include BUSY and OPEN status in Configuration Register (index 02h).
6.4 Alert# Signal
ALERT#/FANIN (pin 6) can be used as ALERT# output or fan tachometer input by setting Configuration Register (index
When the Comparator Mode bit in Configuration Register (index BFh) is asserted, ALERT# is used as a temperature
The F75386’s ALERT# output can be used as a simple interrupt signal if Comparator Mode bit is not asserted. If the
Remote Temperature High Limit
F75386 ALERT# pin
Monitoring Remote Temperature
Remote High Alert Status
-7-
TIME
F75386
July,
V0.27P
2007