k3hb-x Omron Corporation, k3hb-x Datasheet

no-image

k3hb-x

Manufacturer Part Number
k3hb-x
Description
Process Indicator
Manufacturer
Omron Corporation
Datasheet
A Process Indicator Ideal for Discriminating and
Displaying Measurements for Voltage/Current
Signals
• Easy recognition of judgement results using color display that can be
• Equipped with a position meter for monitoring operating status trends.
• External event input allows use in various measurement and discrimina-
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (from behind the front panel), or
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
• Capable of high-speed sampling at 50 times per second (20 ms)
• Easy-to-set two-point scaling allows conversion and display of any user-
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
1. Input Sensor Code
5. Supply Voltage
Optional Board
Sensor Power Supply/Output Boards
Relay/Transistor Output Boards
Event Input Boards
Note: 1. CPA can be combined with relay outputs only.
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs, with 8-pin connector)
K32-BCD: Special BCD Output Cable
K3HB-X@
K33-@
K34-@
K35-@
switched between red and green.
tion applications.
97 mm for DeviceNet models.
set values.
Process Indicator
K3HB-X
VD: DC voltage input
AD: DC current input
VA: AC voltage input
AA: AC current input
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
2. Only one of the following can be used by each Digital Indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
Refer to Safety Precautions for All Digital Panel
Meters.
2
3
4
1
5
Base Units with Optional Boards
2. Sensor Power Supply/Output Type Code
3. Relay/Transistor Output Type Code
4. Event input Type Code
Rubber Packing
Note: Rubber packing is provided with the Controller.
K3HB-X@-@@@
K32-P1
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply
L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply
A: Sensor power supply (12 VDC +/−10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
FLK3A: Communications (RS-485) + Sensor power supply
None: None
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD∗: BCD output + transistor output (NPN open collector: HH/H/PASS/L/
DRT: DeviceNet (See note 2.)
∗ A Special BCD Output Cable (sold separately) is required.
None: None
1: 5 inputs (M3 terminal blocks), NPN open collector
2: 8 inputs (10-pin MIL connector), NPN open collector
3: 5 inputs (M3 terminal blocks), PNP open collector
4: 8 inputs (10-pin MIL connector), PNP open collector
LL)
(12 VDC +/−10%, 80 mA) (See note 1.)
(12 VDC +/−10%, 80 mA) (See note 2.)
(12 VDC +/−10%, 80 mA) (See note 2.)
(12 VDC +/−10%, 80 mA) (See note 2.)
(12 VDC +/−10%, 80 mA) (See note 2.)
1 2 3 4
Model
5
CSM_K3HB-X_DS_E_4_1
1

Related parts for k3hb-x

k3hb-x Summary of contents

Page 1

... Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs, with 8-pin connector) K32-BCD: Special BCD Output Cable CSM_K3HB-X_DS_E_4_1 Base Units with Optional Boards K3HB-X@-@@@ Sensor Power Supply/Output Type Code None: None CPA: Relay output (PASS: SPDT) + Sensor power supply (12 VDC +/− ...

Page 2

... For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0. less: ±0. output for less) K3HB-X 2 ...

Page 3

... EN61000-4- (0. MHz) Power Frequency Magnetic Immunity EN61000-4-8: 30 A/m (50 Hz) continuous time Voltage Dips and Interruptions Immunity EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage sweeps of 5 min each and Z directions 2 2 (100 m/s for relay outputs) 3 times each in 3 axes, 6 directions K3HB-X 3 ...

Page 4

... MΩ − E6 COM 4. The K3HB-XVA@@ complies with UL standards when the applied input voltage is within the range 0 to 150 VAC. If the input voltage is higher than 150 VAC, install an external transformer or take other measures to drop the voltage to 150 VAC or lower. Measurement range Input impedance ± ...

Page 5

... OVER DATA VALID RUN HH H PASS L LL Note: For details on serial and DeviceNet communications, refer to the Digital Indicator K3HB Communications User's Manual (Cat.No. N129). K3HB-X TIMING 24 VDC 50 mA 100 µA max Item Rating Input signal No-voltage contact input ...

Page 6

... Transistor circuit output Micro- computer Drive Relay output X circuit Drive DeviceNet DeviceNet circuit circuit Communi- Drive cations Communications circuit driver COM V O DC-DC Converter (isolated) K3HB-X Drop line length Total drop line (max.) length (max 156 m 6 ...

Page 7

... UP MODE Key Used to switch the Used to change parameters displayed. parameter settings. When changing a set value, this key is used to move along the digits. K3HB display Displays PVs, maximum values, minimum values, parameter names, and error names. Position meter Displays the position of the PV with respect to a desired scale ...

Page 8

... Note: The BCD output connector pin number is the D-sub connector pin number when DC power supply the BCD Output Cable (sold separately) is connected. This number differs from the pin number for the Digital Indicator narrow pitch connector (manufactured by Honda Tsushin Kogyo Co., Ltd.). K3HB-X Data 1 Data Approx ...

Page 9

... K3HB-X 9 ...

Page 10

... Always use a EN/IEC-compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply. • The product must be used indoors for the above applicable standards to apply. • The K3HB-XVA@@ complies with UL standards when the applied input voltage is within the range 0 to 150 VAC. K3HB-X B ...

Page 11

... DDK) Stand: 17L-002A (manufactured by DDK) Wiring Pin No. Signal name 1 N/C 2 S-TMR 3 HOLD 4 RESET 5 N/C 6 COM 7 BANK4 8 BANK2 9 BANK1 10 COM K3HB-X Linear Sensor Indicator K3HB-H K3HB Input B Current input E2 E2 N/C Input COM Voltage input Input Input B B ...

Page 12

... Previous Average Value Comparison Slight changes can be removed from input signals to detect only extreme changes. Input value 2 Input value 1 Input value (inp.a2) (inp.a1) (Reverse scaling) K3HB-X Sampling hold value ON Peak-to-peak value (b2−a2) (b1−a1) b1 'b2 a1 'a2 ...

Page 13

... If interruption memory is ON, the maximum and minimum values after the last resetting will be displayed. • If interruption memory is OFF, the maximum and minimum values will be displayed after the power supply is turned ON (or after the reset input is performed). Input Red 110.01 H 110.00 K3HB-X 13 ...

Page 14

... PASS output terminal. Terminal cover (included) 91 Character Size for Main Display (mm) PV display SV display 14.2 100 (112) 7.6 12 1.3 95 *DeviceNet models Terminal: M3, Terminal Cover: Accessory K3HB-X Hysteresis Hysteresis Input Startup H output compensation time set time H input Panel Cutout Dimensions 120 min. 4.9 3.5 75 min. +0 ...

Page 15

... If the rubber packing is lost or damaged, it can be ordered using the following model number: K32-P1. (Depending on the operating environment, deterioration, contraction, or hardening of the rubber packing may occur and so, in order to ensure the level of waterproofing specified in NEMA4, periodic replacement is recommended.) Note:Rubber packing is provided with the Controller. K3HB-X 15 ...

Page 16

... Doing so may occasionally result in minor or moderate injury due to electric shock. Do not use the equipment for measurements within Measurement Categories III and IV for K3HB-X and II, III, and IV for K3HB-S, K3HB-V, and K3HB-H (according to IEC61010-1). Doing so may occasionally cause unexpected operation, resulting in minor or moderate injury, or damage to the equipment ...

Page 17

... Reception interference may occur if the product is used close to a radio, television, or wireless. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Digital Indicator Digital Indicator K3HB-X 17 ...

Page 18

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.11 ...

Related keywords