Total and Preset Counter Operation
The H7CX has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value.
Batch Counter Operation
The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed.
Note: 1. The batch count value is held at 0 during batch counter reset input.
Dual Counter Operation
Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for
which output turns ON when the set value matches the added or subtracted result.
Note: 1. Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will be calculated based on a CP1 present value of 0.
(1) Dual Count Calculating Mode = ADD
Dual count set value
Reset 1 (CP1 reset)
Reset 2 (CP2 reset)
CP1 present value
CP2 present value
Dual count value
Dual count value = CP1 PV + CP2 PV
OUT1, OUT2
2. If the batch count set value is 0, batch count will be performed but there will be no batch output.
3. The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models).
4. Once batch input has been turned ON, it will return to the ON state after power interruptions.
5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON.
6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value.
2. Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will be calculated based on a CP2 present value of 0.
3. The counting range for the dual count value is 99,999 to 999,999 (0 to 9,999 for 4-digit models).
Total Reset or Reset 2
Note: The above is for when the output mode is N.
The counting ranges for the CP1 present value and CP2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models).
If a present value exceeds 999,999 (9,999 for 4-digit models), FFFFFF (FFFF for 4-digit models) will be displayed to indicate an overflow, and all counting
will stop.
Total count value
Present value
Reset/reset 1
0
0
0
999999
Batch count set value
Batch count value
0
0
Reset 2 (batch
Present value
counter reset)
(Main display)
(batch output)
Note: The full scale (FS) for H7CX 4-digit models is 9999.
Sub-display
Set value
Reset 1
OUT2
OUT1
0
0
Note: The above is for when the output mode is C.
1
(2) Dual Count Calculating Mode = SUB
2
Dual count value = CP1 PV
Dual count set value
Reset 1 (CP1 reset)
Reset 2 (CP2 reset)
CP1 present value
CP2 present value
Dual count value
OUT1, OUT2
Note: The above is for when the output mode is K-2.
or H is selected as the output mode with
6-digit models.
SUB mode can be used only when K-2, D, L,
0
0
0
CP2 PV
• The total counter continues to count the total
• The total count value is reset when the total
• The counting range of the total counter is
• The batch counter continues after count
• Batch output is held until batch counter reset is
• When the batch counter reset input is turned
• If the Reset Key is pressed while the batch
• The count value can be incremented and
• The maximum counting speed for batch counter
• The operation after count completion for the
• The CP1 present value is reset when reset 1
• If the Reset Key is pressed while the dual count
accumulated value when the present value is
reset using reset/reset 1 input (Reset Key).
reset/reset 2 input is turned ON.
If the Reset Key is pressed while the total count
value is displayed, the total count value is reset.
The present value is also reset at this time.
count value returns to 0 when it reaches the full
scale limit.
completion.
input.
ON, the batch count value is reset, and batch
output turns OFF.
count value is displayed, the batch count value
is reset and batch output turns OFF. The
present value is also reset at this time.
decremented.
The batch count is only incremented.
operation is 5 kHz. The batch counter counts
the number of times the count reaches the set
value.
dual counter value is determined by the output
mode.
input is turned ON.
The CP2 present value is reset when reset 2
input is turned ON.
value, CP1 present value, or CP2 present value
is displayed, all of the present values are reset
and outputs turn OFF. At this time, counting is
not possible for CP1 or CP2 inputs.
99,999 to 999,999 ( 999 to 9,999). The total
H7CX-A@-N
Counter
25