njg1666md7 New Japan Radio Co.,Ltd, njg1666md7 Datasheet
njg1666md7
Available stocks
Related parts for njg1666md7
njg1666md7 Summary of contents
Page 1
... The NJG1666MD7operates single bit control switching by control voltage from 1.3V to 4.5V, and includes ESD protection circuits for good ESD tolerance. The NJG1666MD7 is available in a very small, lead-free, halogen-free, 1.6mm x 1.6mm x 0.397 mm, 14-pin EQFN14-D7 package. ...
Page 2
... NJG1666MD7 ! ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL RF Input power P IN Supply voltage V DD Control voltage V CTL Power dissipation P Operating temp. T opr Storage temp. T stg ! ELECTRICAL CHARACTERISTICS 1 (DC) (General conditions PARAMETER SYMBOL Supply voltage V DD Operating current I DD Control voltage (L) V CTL(L) ...
Page 3
... RF noise from outside. Control signal input terminal. This terminal is set to High-Level (+1.3~+4 Low-Level (0~+0.4 V). No connected terminal. This terminal is not connected with internal circuit. Connect to the PCB ground plane. Ground terminal. Connect this terminal with ground plane as close as possible for excellent RF performance. NJG1666MD7 - 3 - ...
Page 4
... NJG1666MD7 ! ELECTRICAL CHARACTERISTICS Isolation vs. Frequency (V =3V CTL 0 PC-P1 (PC-P2 ON)) -10 PC-P2 (PC-P1 ON)) -20 -30 -40 -50 -60 -70 -80 0.0 0.5 1.0 1.5 Frequency (GHz) VSWR vs. Frequency (V =3V CTL 3.0 2.5 2.0 1.5 1.0 0.0 0.5 1.0 1.5 Frequency (GHz) Loss, ISL vs. Input Power (PC-P1 ON, f=2.2GHz, V 0.0 -0.5 -1.0 V =2.0V V =2. -1.5 V =2.5V V =2. =3.0V V =3. =4.0V -2 =4.0V V =4. =4.5V DD -2.5 -3.0 -3 Input Power (dBm) ...
Page 5
... DD V =2. =3. =4. =4. 100 100 o C) NJG1666MD7 Loss vs. Ambient Temperature (PC-P1 ON, V =3V, V =3V) DD CTL f=250MHz f=1000MHz f=2200MHz -50 - Ambient Temperature ( T vs. Ambient Temperature SW (PC-P1/P2, V =3V) CTL( -50 - Ambient Temperature ( ...
Page 6
... NJG1666MD7 ! APPLICATION CIRCUIT P2 ! PARTS LIST Parts ID C1~C4 ! TEST PCB LAYOUT (TOP VIEW) 1pin mark PRECAUTIONS [1] The DC blocking capacitors have to be placed at RF terminal of PC, P1 and P2. [2] For good RF performance, the ground terminals must be placed possibly close to ground plane of substrate, and through holes for GND should be placed near by the pin connection. ...
Page 7
... Do NOT chemically make gas or powder with this product. • To waste this product, please obey the relating law of your country. This product may be damaged with electric static discharge (ESD) or spike voltage. Please handle with care to avoid these damages. NJG1666MD7 Units : mm Board ...