71m6515h Maxim Integrated Products, Inc., 71m6515h Datasheet - Page 44

no-image

71m6515h

Manufacturer Part Number
71m6515h
Description
71m6515h Energy Meter Ic
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71m6515h-IGT
Manufacturer:
TERIDIAN
Quantity:
317
Part Number:
71m6515h-IGT
Manufacturer:
TERIDIA
Quantity:
20 000
Part Number:
71m6515h-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71m6515h-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71m6515h-IGTW
Manufacturer:
TERIDIAN
Quantity:
80
Part Number:
71m6515h-IGTW
Manufacturer:
TERIDIAN
Quantity:
20 000
Part Number:
71m6515h-IGTW/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
START_THRESHLD (0x40)
VI_PTHRESHOLD (0x17)
Page: 44 of 57
This register holds the voltage and current thresholds that apply to the calculation of frequency, zero crossings, voltage
phase and energy values. If the current is below the value stored in I_START, calculation of RMS current, and energy (Wh,
VARh and VAh) is suppressed.
Bits 15-0: These bits (I_START) hold the threshold to be applied for under-current. If ISQSUM< I_START, all post-
processed values are set to zero for that phase. This includes reported values for Wh, VARh, VAh, IRMS, VPHASE,
IPHASE, PULSER, PULSEW, PULSE3 and PULSE4. This applies only if CREEP_THRSLD is not set to zero. One LSB is
defined as:
Elements with ISQSUM< I_START will set the creep bits in the STATUS register.
Bits 31-16: These bits (V_START). hold the threshold to be applied for under-voltage. If VRMS<V_START, the values for
frequency (register FREQ_DELTA_T), zero crossings (register MAIN_EDGE_CNT), and voltage phase (register
V_PHASE_ABC) are set to zero. Additionally, if VRMS< V_START, the reported value of VRMS is set to zero. One LSB is
defined as:
Elements with VRMS< V_START will not set the creep bits in the STATUS register.
This register holds the threshold for over-voltage and over-current alarms.
Bits 15-0: These bits (I_PTHRESHOLD) hold the threshold to applied for over-current alarm. The threshold comparison is
applied to the upper 16 bits of the values in IRMS: One LSB is defined as:
Bits 31-16: These bits (V_PTHRESHOLD). hold the threshold to applied for over-voltage alarm. The threshold comparison
is applied to the upper 16 bits of the values in VRMS One LSB is defined as:
LSB
LSB
LSB
LSB
Four periods translate to T = 4 * 20ms = 80ms. This means that
Example: A meter operating at 50Hz and 240V (RMS) is supposed to apply a sag threshold of 180V (RMS) for
180V (RMS) translate to 255V (peak), so SAGTHR is determined by
of 520V (RMS) and an over-current threshold of 400A (RMS). Which values are to be selected for
at least four periods before a sag warning is issued. VMAX is 600V. Which values are to be selected for SAG?
=
=
=
=
Example: A meter designed with VMAX=600V and IMAX=208A is supposed to apply an overvoltage threshold
V_PTHRESHOLD and I_PTHRESHOLD?
SAGTHR
VMAX
450
IMAX
In
SAG_CNT = T/397μs = 202.
In
SUM
450
_
.
_
8
76
8
.
2
76
2
SUM
10
_
=
. 9
2
CYCLES
10
16
LSB
4045
6
255
VMAX
_
. 9
6
CYCLES
4045
IMAX
=
10
. 7
8798
13
V
10
© 2005-2008 TERIDIAN Semiconductor Corporation
A
rms
2
h
13
2
V
255
A
16
rms
2
h
10
9
600
=
823
Energy Meter IC
DATA SHEET
71M6515H