71m6515h Maxim Integrated Products, Inc., 71m6515h Datasheet - Page 36

no-image

71m6515h

Manufacturer Part Number
71m6515h
Description
71m6515h Energy Meter Ic
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71m6515h-IGT
Manufacturer:
TERIDIAN
Quantity:
317
Part Number:
71m6515h-IGT
Manufacturer:
TERIDIA
Quantity:
20 000
Part Number:
71m6515h-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71m6515h-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71m6515h-IGTW
Manufacturer:
TERIDIAN
Quantity:
80
Part Number:
71m6515h-IGTW
Manufacturer:
TERIDIAN
Quantity:
20 000
Part Number:
71m6515h-IGTW/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Page: 36 of 57
It is important to note that the length of the accumulation interval, as determined by SUM_CYCLES, is not an exact multiple
of 1000ms. For example, if SUM_CYCLES = 60, the resulting accumulation interval is:
Since the signal at the input selected with F_SELECT is used to synchronize filters and other processing stages in the CE,
accuracy for most measurements will be reduced if no voltage is present at the selected phase input. Accuracy can be
established by selecting the phase that carries a stable signal (A, B, or C).
Bits 13-8: These six bits (SUM_CYCLES) define the length of the accumulation interval τ per the formula:
Allowed values are 24 (400ms) through 60 (1000ms), unless the post-processor is disabled. Bit 8 is the LSB.
This means that accurate time measurements should be based on the RTC, not the accumulation interval.
Bit 14: This bit (CKOUT_DISB) disables the CKOUT pin when set. The CKOUT pin can be used for diagnostics. For EMC
compliance and power saving reasons, CKOUT_DISB should always be set.
Bit 15: This bit (ADC_DIS) disables the ADC when set, e.g. to save power. Of course, no metering or measuring can be
performed with the ADC disabled.
Bits 18-16: These three bits (TMUX) select the source for the TMUX diagnostic output pin. For EMC compliance and
power saving reasons, TMUX should be zero (default) if unused.
Bits 20-19: These two bits (F_SELECT) select the phase that is to be used for frequency measurement. The frequency will
be shown in bits 31-16 of the FREQ_DELTA_T register (and as bit 4 of the STATUS word – in this form as a digitized zero
crossing signal).
Bit 21: This bit (CE_ONLY) disables the post-processor when set to 1. When the post-processor is disabled, the time-
intensive computations of IPHASE, IRMS, VAh and VRMS are not performed, and therefore smaller accumulation times
(SUM_CYCLES < 24) are permitted. In this case, the host is responsible for calculating IPHASE, IRMS, VAh and VRMS.
τ
=
SUM
_
TMUX2
2520
Bit 18
CYCLES
0
0
0
0
1
1
1
1
6 .
TMUX1
42
Bit 17
F_SELECT1
0
0
1
1
0
0
1
1
Bit 20
0
0
1
1
© 2005-2008 TERIDIAN Semiconductor Corporation
τ
=
TMUX0
Bit 16
32768
0
1
0
1
0
1
0
1
60
F_SELECT0
13
Bit 19
42
Hz
0
1
0
1
TMUX
=
0
1
2
3
4
5
6
7
2520
2520
F_SELECT
.
62
Signal Selected for the TMUX Pin
GND
MUX_SYNC
RTM
RTC Output
CE_BUSY
XFER_BUSY
VX_OK (Comparator Output)
V3P3/2 =1.5V internal analog voltage
0
1
2
3
Hz
=
999
Phase
Selected
Phase A
Phase B
Phase C
Not allowed
.
75
ms
Energy Meter IC
DATA SHEET
71M6515H
MARCH 2008
V1.4