RSD-300D-48 Mean Well Enterprises, RSD-300D-48 Datasheet

no-image

RSD-300D-48

Manufacturer Part Number
RSD-300D-48
Description
RSD-300 series 300WRailway Single Output DC-DC Converter
Manufacturer
Mean Well Enterprises
Datasheet
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE
RANGE
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
RAILWAY STANDARD
MTBF
DIMENSION
PACKING
OVER TEMPERATURE
300W Railway Single Output DC-DC Converter
CONTINUOUS
1 SEC.
Note.3
Note.2
RSD-300B-12
800ms, 50ms at full load
B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
45A/24VDC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +55
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
Meet IEC60950-1(LVD)
I/P-O/P:4KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B ; EN50155(EN50121-3-2)
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A ; EN50121-3-2
Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
130.7K hrs min.
216*97*40mm (L*W*H)
1.19Kg ; 12pcs/15.3Kg/1.12CUFT
89%
14.6A/24V
13.8 ~ 16.2V
B/C- type : 110
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
12V
22.5A
0 ~ 22.5A
270W
120mVp-p
0.03%/
2.0%
0.3%
1.0%
(0 ~ 55 )
(no derating) ; +70
RSD-300B-24 RSD-300B-48
27.6 ~ 32.4V 55.2 ~ 64.8V
24V
11.3A
0 ~ 11.3A
271.2W
150mVp-p
89%
14.6A/24V
2.0%
0.2%
1.0%
I/P-FG:2.5KVDC
MIL-HDBK-217F (25 )
5 (TSW1)
89%
14.6A/24V
48V
5.7A
0 ~ 5.7A
273.6W
180mVp-p
2.0%
0.5%
1.0%
detect on main power transformer
@ 60% load by free air convection ; +70
O/P-FG:2.5KVDC
RSD-300C-12
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
91%
7.2A/48V
45A/48VDC
13.8 ~ 16.2V
12V
25A
0 ~ 25A
300W
120mVp-p
www.DataSheet.net/
2.0%
0.3%
1.0%
RSD-300C-24 RSD-300C-48
7.2A/48V
27.6 ~ 32.4V 55.2 ~ 64.8V
24V
12.5A
0 ~ 12.5A
300W
150mVp-p
91%
2.0%
0.2%
1.0%
; D-type : 115
6.3A
91%
7.2A/48V
48V
0 ~ 6.3A
302.4W
180mVp-p
no derating with external base plate, Tx class compliance
2.0%
0.5%
1.0%
R S D - 3 0 0
5 (TSW1)
RSD-300D-12
13.8 ~ 16.2V
12V
25A
0 ~ 25A
300W
120mVp-p
67.2 ~ 143VDC
57.6 ~ 154VDC
91%
3.1A/110V
45A/110VDC
2.0%
0.2%
1.0%
detect on main power transformer
File Name:RSD-300-SPEC 2012-05-07
RSD-300D-24 RSD-300D-48
12.5A
91%
3.1A/110V
27.6 ~ 32.4V 55.2 ~ 64.8V
24V
0 ~ 12.5A
300W
150mVp-p
2.0%
0.2%
1.0%
s e r i e s
91%
3.1A/110V
48V
6.3A
0 ~ 6.3A
302.4W
180mVp-p
2.0%
0.5%
1.0%
Datasheet pdf - http://www.DataSheet4U.co.kr/

Related parts for RSD-300D-48

RSD-300D-48 Summary of contents

Page 1

... I/P-FG:2.5KVDC O/P-FG:2.5KVDC MIL-HDBK-217F ( RSD-300D-12 RSD-300D-24 RSD-300D-48 48V 12V 24V 48V 6.3A 25A 12. 25A 0 ~ 12. 6.3A 302.4W 300W 300W 302.4W 180mVp-p ...

Page 2

... Case No.205A Unit:mm 15max O Assignment DC OUTPUT -V DC OUTPUT +V fosc : 130KHz RECTIFIERS +V & -V FILTER DETECTION CIRCUIT 350 300 250 200 150 100 105 115 125 135 145 154 INPUT VOLTAGE (V) File Name:RSD-300-SPEC 2012-05-07 Datasheet pdf - http://www.DataSheet4U.co.kr/ ...

Page 3

... To fulfil the requirements of EN50155 TX level, RSD-300 series must be installed onto an iron plate on the bottom. In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-300 series must be firmly mounted at the center of the iron plate, as shown in the diagram above. ...

Page 4

... Duration: 10 mins Temperature: 19 Humidity: 65% Duration: 5 hrs Temperature Humidity Duration: 30ms*18 Temperature: -40 Dwell Time: 16 hrs Temperature: 35 Duration: 96 hrs www.DataSheet.net Test conditions Status No damage / 85 PASS PASS PASS PASS PASS PASS 2 PASS File Name:RSD-300-SPEC 2012-05-07 Datasheet pdf - http://www.DataSheet4U.co.kr/ ...

Related keywords