RSD-200B-12 MEANWELL [Mean Well Enterprises Co., Ltd.], RSD-200B-12 Datasheet

no-image

RSD-200B-12

Manufacturer Part Number
RSD-200B-12
Description
200W Railway Single Output DC-DC Converter
Manufacturer
MEANWELL [Mean Well Enterprises Co., Ltd.]
Datasheet
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
EMC EMISSION
EMC IMMUNITY
RAILWAY STANDARD
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE
RANGE
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
MTBF
DIMENSION
PACKING
OVER TEMPERATURE
200W Railway Single Output DC-DC Converter
CONTINUOUS
1 SEC.
Note.3
Note.2
RSD-200B-12
800ms, 50ms at full load
3 ~ 30ms @ full load ; B/C- type comply with S1 level ; D-type comply with S2 level
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
45A/24VDC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +55
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
Meet IEC60950-1(LVD)
I/P-O/P:4KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B ; EN50155(EN50121-3-2)
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A ; EN50121-3-2
Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
218.2K hrs min.
191*86*40mm (L*W*H)
0.94Kg; 12pcs/12.3Kg/0.8CUFT
90
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
89%
9.6A/24V
13.8 ~ 16.2V
12V
16.7A
0 ~ 16.7A
200.4W
120mVp-p
0.03%/
2.0%
0.2%
1.0%
5 (TSW1) detect on heatsink of power transistor
(0 ~ 50 )
(no derating) ; +70
RSD-200B-24
89%
9.6A/24V
27.6 ~ 32.4V
24V
8.4A
0 ~ 8.4A
201.6W
150mVp-p
2.0%
0.2%
1.0%
I/P-FG:2.5KVDC
MIL-HDBK-217F (25 )
RSD-200B-48
48V
4.2A
0 ~ 4.2A
201.6W
180mVp-p
89%
9.6A/24V
55.2 ~ 64.8V
2.0%
0.5%
1.0%
@ 60% load by free air convection ; +70
O/P-FG:2.5KVDC
RSD-200C-12
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
91%
4.8A/48V
45A/48VDC
13.8 ~ 16.2V
12V
16.7A
0 ~ 16.7A
200.4W
120mVp-p
2.0%
0.2%
1.0%
RSD-200C-24
8.4A
91%
4.8A/48V
27.6 ~ 32.4V
24V
0 ~ 8.4A
201.6W
150mVp-p
2.0%
0.2%
1.0%
RSD-200C-48
4.2A
91%
4.8A/48V
55.2 ~ 64.8V
48V
0 ~ 4.2A
201.6W
180mVp-p
2.0%
0.5%
1.0%
(no derating with external base plate)
R S D - 2 0 0
RSD-200D-12
16.7A
67.2 ~ 143VDC
57.6 ~ 154VDC
91%
2.1A/110V
45A/110VDC
13.8 ~ 16.2V
12V
0 ~ 16.7A
200.4W
120mVp-p
2.0%
0.2%
1.0%
File Name:RSD-200-SPEC 2012-03-09
RSD-200D-24
8.4A
91%
2.1A/110V
27.6 ~ 32.4V
24V
0 ~ 8.4A
201.6W
150mVp-p
2.0%
0.2%
1.0%
s e r i e s
RSD-200D-48
4.2A
0 ~ 4.2A
201.6W
180mVp-p
91%
2.1A/110V
55.2 ~ 64.8V
48V
2.0%
0.5%
1.0%

Related parts for RSD-200B-12

RSD-200B-12 Summary of contents

Page 1

... Railway Single Output DC-DC Converter SPECIFICATION MODEL RSD-200B-12 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note.2 OUTPUT VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ 30ms @ full load ; B/C- type comply with S1 level ; D-type comply with S2 level CONTINUOUS 16 ...

Page 2

... LED O Pin No. Assignment 1 DC OUTPUT - OUTPUT +V fosc : 130KHz RECTIFIERS & FILTER DETECTION CIRCUIT O.V. 105 115 125 135 145 INPUT VOLTAGE (V) File Name:RSD-200-SPEC 2012-03- Unit: 350 300 250 200 150 100 50 154 ...

Related keywords