HY27US08281A Hynix Semiconductor, HY27US08281A Datasheet - Page 39

no-image

HY27US08281A

Manufacturer Part Number
HY27US08281A
Description
128mbit 16mx8bit / 8mx16bit Nand Flash Memory
Manufacturer
Hynix Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HY27US08281A
Manufacturer:
HY
Quantity:
1 000
Part Number:
HY27US08281A
Manufacturer:
HY
Quantity:
1 000
Part Number:
HY27US08281A
Manufacturer:
HY
Quantity:
1 000
Part Number:
HY27US08281A-TP
Manufacturer:
HYNIX/海力士
Quantity:
20 000
Part Number:
HY27US08281A-TPCB
Manufacturer:
HYNIX
Quantity:
11 200
Part Number:
HY27US08281A-TPCB
Manufacturer:
ROHM
Quantity:
56
Part Number:
HY27US08281A-TPCB
Manufacturer:
HYNIX/海力士
Quantity:
20 000
HY27US(08/16)281A Series
128Mbit (16Mx8bit / 8Mx16bit) NAND Flash
Bad Block Management
Devices with Bad Blocks have the same quality level and the same AC and DC characteristics as devices where all the
blocks are valid. A Bad Block does not affect the performance of valid blocks because it is isolated from the bit line and
common source line by a select transistor. The devices are supplied with all the locations inside valid blocks
erased(FFh).The Bad Block Information is written prior to shipping. Any block where the 6th Byte/ 1st Word in the
spare area of the 1st or 2nd page (if the 1st page is Bad) does not contain FFh is a Bad Block. The Bad Block Informa-
tion must be read before any erase is attempted as the Bad Block Information may be erased. For the system to be
able to recognize the Bad Blocks based on the original information it is recommended to create a Bad Block table fol-
lowing the flowchart shown in Figure 31. The 1st block, which is placed on 00h block address is guaranteed to be a
valid block.
Block Replacement
Over the lifetime of the device additional Bad Blocks may develop. In this case the block has to be replaced by copying
the data to a valid block. These additional Bad Blocks can be identified as attempts to program or erase them will give
errors in the Status Register.
As the failure of a page program operation does not affect the data in other pages in the same block, the block can be
replaced by re-programming the current data and copying the rest of the replaced block to an available valid block.The
Copy Back Program command can be used to copy the data to a valid block.
See the “Copy Back Program” section for more details.
Refer to Table 17 for the recommended procedure to follow if an error occurs during an operation.
Operation
Recommended Procedure
Erase
Block Replacement
Program
Block Replacement or ECC
Read
ECC
Table 17: Block Failure
Figure 31: Bad Block Management Flowchart
Rev 0.6 / Nov. 2005
39

Related parts for HY27US08281A