Datasheets

Specifications of ATxmega192A3

Flash (kbytes)
192 Kbytes
Pin Count
64
Max. Operating Frequency
32 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
50
Ext Interrupts
50
Usb Speed
No
Usb Interface
No
Spi
10
Twi (i2c)
2
Uart
7
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
AES/DES
Sram (kbytes)
16
Eeprom (bytes)
2048
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.6 to 3.6
Operating Voltage (vcc)
1.6 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
7
Output Compare Channels
22
Input Capture Channels
22
Pwm Channels
22
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATxmega192A3-AU
Manufacturer:
TOSHIBA
Quantity:
1 200
Part Number:
ATxmega192A3-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega192A3-MH
Manufacturer:
TI/NSC
Quantity:
56
Part Number:
ATxmega192A3U-AU
Manufacturer:
MSDS
Quantity:
124
Part Number:
ATxmega192A3U-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega192A3U-AUR
Manufacturer:
Atmel
Quantity:
10 000
22. IRCOM - IR Communication Module
22.1
22.2
8077H–AVR–12/09
Features
Overview
XMEGA contains an Infrared Communication Module (IRCOM) IrDA 1.4 compatible module for
baud rates up to 115.2 kbps. This supports three modulation schemes: 3/16 of baud rate period,
fixed programmable pulse time based on the Peripheral Clock speed, or pulse modulation dis-
abled. There is one IRCOM available, and this can be connected to any USART to enable
infrared pulse coding/decoding for that USART.
Figure 22-1. IRCOM connection to USARTs and associated port pins
The IRCOM is automatically enabled when a USART is set in IRCOM mode. When this is done
signals between the USART and the RX/TX pins are routed through the module as shown in
ure 22-1 on page
input for the IRCOM receiver. This will disable the RX input from the USART pin.
Pulse modulation/demodulation for infrared communication
IrDA 1.4 Compatible for baud rates up to 115.2 kbps
Selectable pulse modulation scheme
Built in filtering
Can be connected to and used by any USART
– 3/16 of baud rate period
– Fixed pulse period, 8-bit programmable
– Pulse modulation disabled
IRCOM
Decoding
Encoding
Pulse
Pulse
256. It is also possible to select an Event Channel from the Event System as
encoded RXD
decoded TXD
decoded RXD
encoded TXD
Event System
USARTxn
....
DIF
USARTD0
USARTC0
events
RXDnx
TXDnx
XMEGA A
RXD...
TXD...
RXDD0
TXDD0
RXDC0
TXDC0
Fig-
256

Related parts for ATxmega192A3