DS2155L Maxim Integrated Products, DS2155L Datasheet - Page 180
DS2155L
Manufacturer Part Number
DS2155L
Description
IC TXRX T1/E1/J1 1-CHIP 100-LQFP
Manufacturer
Maxim Integrated Products
Specifications of DS2155L
Function
Single-Chip Transceiver
Interface
E1, HDLC, J1, T1
Number Of Circuits
1
Voltage - Supply
3.14 V ~ 3.47 V
Current - Supply
75mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LQFP
Includes
BERT Generator and Detector, CMI Coder and Decoder, HDLC Controller
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS2155L
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS2155L+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS2155LB
Manufacturer:
DALLAS
Quantity:
20 000
Company:
Part Number:
DS2155LC2+
Manufacturer:
Infineon
Quantity:
95
Company:
Part Number:
DS2155LNB+
Manufacturer:
Maxim
Quantity:
100
Company:
Part Number:
DS2155LNC2+
Manufacturer:
ROHM
Quantity:
2 000
Part Number:
DS2155LNC2+
Manufacturer:
MAXIM/美信
Quantity:
20 000
27.
An error-insertion function is available in the DS2155 and is used to create errors in the payload portion
of the T1 frame in the transmit path. This function is only available in T1 mode. Errors can be inserted
over the entire frame or the user can select which channels are to be corrupted. Errors are created by
inverting the last bit in the count sequence. For example, if the error rate 1 in 16 is selected, the 16th bit is
inverted. F-bits are excluded from the count and are never corrupted. Error rate changes occur on frame
boundaries. Error-insertion options include continuous and absolute number with both options supporting
selectable insertion rates.
Table 27-A. Transmit Error-Insertion Setup Sequence
STEP
2A
2B
or
1
PAYLOAD ERROR-INSERTION FUNCTION (T1 MODE ONLY)
Enter desired error rate in the ERC register. Note: If ER3 through ER0 = 0, no errors
are generated even if the constant error-insertion feature is enabled.
For constant error insertion, set CE = 1 (ERC.4).
For a defined number of errors:
–
–
–
Set CE = 0 (ERC.4)
Load NOE1 and NOE2 with the number of errors to be inserted
Toggle WNOE (ERC.7) from 0 to 1 to begin error insertion