STEVAL-PCC010V2 STMicroelectronics, STEVAL-PCC010V2 Datasheet - Page 16

no-image

STEVAL-PCC010V2

Manufacturer Part Number
STEVAL-PCC010V2
Description
BOARD EVAL FOR ST802RT1A
Manufacturer
STMicroelectronics
Series
-r

Specifications of STEVAL-PCC010V2

Design Resources
STEVAL-PCC010V2 BOM STEVAL-PCC010V2 Schematic
Main Purpose
Interface, Ethernet Controller (PHY and MAC)
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
ST802RT1A, STM32F207
Primary Attributes
1 Port, 100BASE-TX/10BASE-T
Secondary Attributes
MII, RMII
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-11465

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-PCC010V2
Manufacturer:
STMicroelectronics
Quantity:
1
Configuration and functionality
16/34
Table 1.
1. See functionality of AN_xxx pins in the ST802RT1 datasheet.
PHY MII address
The MDIO/MDC serial management interface is used to access the internal registers of the
PHY. The Ethernet MAC that is connected to the PHY must know the appropriate PHY
address for successful communication. A special case is the PHY address 0x00. If this
address is used as the bootstrap address during the reset, the 00000 value is latched into
the internal receive mode control register RN14 (0x14h) but the PHY goes also to isolation
mode. It is possible to change the PHY address by writing the RN14 register later when the
application is already running.
Table 2.
Power-down
This pin is an active low input of the PHY and should be asserted low to put the device into
power-down mode. During power-down mode, TXP/TXN outputs and all LED outputs are 3-
stated, and the MII interface is isolated. The power-down functionality is also achievable
through software by asserting bit 11 of register RN00.
Table 3.
Loopback
Local loopback passes data internally from the transmitting to the receiving serial analog
logic. There are two ways to enter the internal loopback mode, either by writing RN00
Jumper
Jumper
Jumper
JP16
JP17
JP18
JP11
JP12
JP13
JP14
JP15
JP1
Auto-negotiation jumper settings
PHY MII address jumper settings
Power-down jumper setting
AN_1
AN_0
AN_EN - auto-negotiation enable; when “high” - auto-
negotiation enabled, when “low” - auto-negotiation disabled
Power-down, if fitted - PHY works normally; if not fitted -
PHY is in power-down mode
Doc ID 18370 Rev 1
MII address 0
MII address 1
MII address 2
MII address 3
MII address 4
Description
Description
Description
(1)
configuration
configuration
configuration
Default
Default
Default
Fitted
High
Low
Low
Low
Low
High
High
High
UM1041

Related parts for STEVAL-PCC010V2