AT49BV320AT-70TI Atmel, AT49BV320AT-70TI Datasheet - Page 6

no-image

AT49BV320AT-70TI

Manufacturer Part Number
AT49BV320AT-70TI
Description
Manufacturer
Atmel
Datasheet

Specifications of AT49BV320AT-70TI

Cell Type
NOR
Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP-I
Program/erase Volt (typ)
2.65 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.65V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
25mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant
Any commands written to the chip during the embedded programming cycle will be ignored. If
a hardware reset happens during programming, the data at the location being programmed
will be corrupted. Please note that a data “0” cannot be programmed back to a “1”; only erase
operations can convert “0”s to “1”s. Programming is completed after the specified t
cycle
BP
time. The Data Polling feature or the Toggle Bit feature may be used to indicate the end of a
program cycle. If the erase/program status bit is a “1”, the device was not able to verify that the
erase or program operation was performed successfully.
VPP PIN: The circuitry of the AT49BV32XA(T) is designed so that the device cannot be pro-
grammed or erased if the V
voltage is less that 0.4V. When V
is at 0.9V or above, normal
PP
PP
program and erase operations can be performed. The VPP pin cannot be left floating.
PROGRAM/ERASE STATUS: The device provides several bits to determine the status of a
program or erase operation: I/O2, I/O3, I/O5, I/O6 and I/O7. The “Status Bit Table” on page 12
and the following four sections describe the function of these bits. To provide greater flexibility
for system designers, the AT49BV32XA(T) contains a programmable configuration register.
The configuration register allows the user to specify the status bit operation. The configuration
register can be set to one of two different values, “00” or “01”. If the configuration register is set
to “00”, the part will automatically return to the read mode after a successful program or erase
operation. If the configuration register is set to a “01”, a Product ID Exit command must be
given after a successful program or erase operation before the part will return to the read
mode. It is important to note that whether the configuration register is set to a “00” or to a “01”,
any unsuccessful program or erase operation requires using the Product ID Exit command to
return the device to read mode. The default value (after power-up) for the configuration regis-
ter is “00”. Using the four-bus cycle Set Configuration Register command as shown in the
“Command Definition in Hex” table on page 13, the value of the configuration register can be
changed. Voltages applied to the RESET pin will not alter the value of the configuration regis-
ter. The value of the configuration register will affect the operation of the I/O7 status bit as
described below.
DATA POLLING: The AT49BV32XA(T) features Data Polling to indicate the end of a program
cycle. If the status configuration register is set to a “00”, during a program cycle an attempted
read of the last byte/word loaded will result in the complement of the loaded data on I/O7.
Once the program cycle has been completed, true data is valid on all outputs and the next
cycle may begin. During a chip or sector erase operation, an attempt to read the device will
give a “0” on I/O7. Once the program or erase cycle has completed, true data will be read from
the device. Data Polling may begin at any time during the program cycle. Please see “Status
Bit Table” on page 12 for more details.
If the status bit configuration register is set to a “01”, the I/O7 status bit will be low while the
device is actively programming or erasing data. I/O7 will go high when the device has com-
pleted a program or erase operation. Once I/O7 has gone high, status information on the other
pins can be checked.
The Data Polling status bit must be used in conjunction with the erase/program and V
status
PP
bit as shown in the algorithm in Figures 1 and 2 on page 10.