MY2F-DC6 Omron, MY2F-DC6 Datasheet - Page 5

no-image

MY2F-DC6

Manufacturer Part Number
MY2F-DC6
Description
RELAY DPDT 6VDC
Manufacturer
Omron
Series
MYr
Datasheet

Specifications of MY2F-DC6

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Non Latching
Coil Current
151mA
Coil Voltage
6VDC
Turn On Voltage (max)
4.8 VDC
Turn Off Voltage (min)
0.6 VDC
Features
-
Mounting Type
Chassis Mount
Termination Style
Solder Lug
Contact Material
Silver (Ag)
Operate Time
20ms
Release Time
20ms
Coil Power
900 mW
Coil Resistance
39.8 Ohms
Operating Temperature
-55°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MY2FDC6
MY
Non-latching
Latching
Note: Data shown are of initial value.
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
CHARACTERISTICS
Mechanically
Under rated load
Single contact type
Bifurcated contact type
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Mechanically
Electrically
Mechanically
Under rated load
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Electrically
50 m
20 ms max.
20 ms max.
18,000 operations/hour
1,800 operations/hour
100 M
Unsealed: 2,000 VAC, 50/60 Hz for 1 minute
Sealed:
Hermetically sealed: 1,000 VAC, 50/60 Hz for 1 minute
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
Unsealed: -55 to 70 C (-67 to 158 F)
Sealed:
Hermetically sealed: 25 to 60 C (77 to 140 F)
35% to 85% RH
Single contact type:
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
Bifurcated contact type:
AC: 50 million operations min.
DC: 20 million operations min. (5 million operations for the sealed/hermetically
sealed types) (at operating frequency of 1,800 operations/hour)
See “Characteristic Data”
Sealed/unsealed: Approx. 35 g (1.23 oz)
Hermetically sealed: Approx. 50 g (1.76 oz)
50 m
AC: 30 ms max.; DC: 15 ms max.
AC: 30 ms max.; DC: 15 ms max.
18,000 operations/hour
1,800 operations/hour
100 M
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity, and between
set and reset coils
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
-55 to 70 C (-67 to 158 F)
45% to 85% RH
100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
Approx. 30 g (1.06 oz)
max.
max.
2
2
min. (at 500 VDC)
min. (at 500 VDC)
(approx. 20 G)
(approx. 20 G)
2
2
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
700 VAC, 50/60 Hz for 1 minute between contacts of same polarity
-55 to 60 C (-67 to 140 F)
(approx. 100 G)
(approx. 100 G)
MY
5

Related parts for MY2F-DC6