MY4-DC100/110-EL Omron, MY4-DC100/110-EL Datasheet - Page 17

no-image

MY4-DC100/110-EL

Manufacturer Part Number
MY4-DC100/110-EL
Description
RELAY GP 4PDT 100/110VDC
Manufacturer
Omron
Series
MYr
Datasheet

Specifications of MY4-DC100/110-EL

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
3A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Non Latching
Coil Current
9mA
Coil Voltage
110VDC
Turn On Voltage (max)
88 VDC
Turn Off Voltage (min)
11 VDC
Features
-
Mounting Type
Socketable
Termination Style
Plug In
Contact Material
Silver (Ag)
Operate Time
20ms
Release Time
20ms
Coil Power
900 mW
Coil Resistance
11.1K Ohms
Operating Temperature
-55°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MY4DC100110EL
Examples of Applicable Wires (Confirmed Using Catalog Information)
■ Wiring
Use wires of the applicable sizes specified above. The length of the
exposed conductor should be 8 to 9 mm.
Use the following wiring procedure.
1. Insert the specified screwdriver into the release hole located
Fig. 2 Wire Connection Holes and Release Holes
Wire connection holes
Type of wire
Equipment wire 2491X
BS6004
Switchgear BS6231
Switchgear BS6231
Tri-rated control and switchgear
Conduit
UL1007
UL1015
UL1061
UL1430
Fig. 1 Exposed Conductor Length
Fig. 3 Section A-A of Fig. 2
beside the wire connection hole where the wire is to be inserted.
Release holes
8 to 9 mm
Wire connection hole
Release hole
Conductor type
Flexible
Solid
Flexible
Stranded
Flexible
Flexible
Flexible
Flexible
Solid
Flexible
Screwdriver
Insert
See note 1, above.
0.5 mm
18AWG
18AWG
18AWG
2
2. Insert the exposed conductor into the wire connection hole.
3. Pull out the screwdriver.
Note: Use no more than 2 wires per terminal, 1 wire per hole.
Recommended wire sizes See note 2, above.
0.5, 0.75, 1.0 mm
1.0 mm
0.5, 0.75 mm
0.5, 0.75, 1.0, 1.5 mm
1.5 mm
16AWG
18AWG, 16AWG
16AWG
General-purpose Relay
2
2
2
2
2
Insert
1.5 mm
1.5 mm
1.0 mm
MY
2
2
2
Pull out
275

Related parts for MY4-DC100/110-EL