MAX9249GCM/V+ Maxim Integrated Products, MAX9249GCM/V+ Datasheet - Page 15

no-image

MAX9249GCM/V+

Manufacturer Part Number
MAX9249GCM/V+
Description
IC SERIALIZER GMSL LVDS 48TQFP
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX9249GCM/V+

Function
Serializer
Data Rate
2.5Gbs
Input Type
LVDS
Output Type
Serial
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
48-TQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Outputs
-
Number Of Inputs
-
Table 1. Power-Up Default Register Map (see Table 12)
The MAX9249 serializer with LVDS system interface
utilizes Maxim’s GMSL technology. The MAX9249 serial-
izer pairs with any GMSL deserializer to form a complete
digital serial link for joint transmission of high-speed
video, audio, and control data.
The MAX9249 allows a maximum serial payload data
rate of 2.5Gbps for a greater than 15m STP cable. The
serializer operates up to a maximum clock of 104MHz for
a 3-channel LVDS input or 78MHz for a 4-channel LVDS
input. This serial link supports display panels from QVGA
(320 x 240) up to WXGA (1280 x 800) with 24-bit color.
The 3-channel mode handles three lanes of LVDS data
(21 bits), UART control signals, and three audio signals.
The 4-channel mode handles four lanes of LVDS data
(28 bits), UART control signals, three audio signals, and/
or up to three auxiliary parallel inputs. The three audio
inputs form a standard I
rates from 8kHz to 192kHz and audio word lengths of
4 to 32 bits. The embedded control channel forms a
full-duplex, differential, 100kbps to 1Mbps UART link
between the serializer and deserializer. The ECU, or FC,
can be located on the MAX9249 side of the link (typical
REGISTER
ADDRESS
(HEX)
0x00
0x01
0x02
0x03
______________________________________________________________________________________
POWER-UP
0x1F, 0x3F
DEFAULT
(HEX)
0x80
0x90
0x00
Detailed Description
Serializer with LVDS System Interface
2
S interface, supporting sample
SERID =1000000, serializer device address is 1000 000
RESERVED = 0
DESID =1001000, deserializer device address is 1001 000
RESERVED = 0
SS = 000 (SSEN = low), SS = 001 (SSEN = high), spread-spectrum settings depend on
SSEN pin state at power-up
AUDIOEN = 1, I
PRNG = 11, automatically detect the pixel clock range
SRNG = 11, automatically detect serial-data rate
AUTOFM = 00, calibrate spread-modulation rate only once after locking
SDIV = 000000, autocalibrate sawtooth divider
Gigabit Multimedia Serial Link
2
S channel enabled
POWER-UP DEFAULT SETTINGS
for video display), on the deserializer side of the link (typ-
ical for image sensing), or on both sides. In addition, the
control channel enables ECU/FC control of peripherals
in the remote side, such as backlight control, grayscale
Gamma correction, camera module, and touch screen.
Base-mode communication with peripherals uses either
I
full-duplex communication using custom UART formats.
The MAX9249 serializer driver preemphasis, along with
the channel equalizer on the GMSL deserializer, extends
the link length and enhances the link reliability. Spread
spectrum is available on the MAX9249 to reduce EMI on
the serial link and the parallel output of the GMSL dese-
rializer. The serial output complies with ISO 10605 and
IEC 61000-4-2 ESD protection standards.
The FC configures various operating conditions of the
MAX9249 and GMSL deserializer through internal regis-
ters. The default device addresses stored in the R0 and
R1 registers of both the MAX9249 and GSML deserial-
izer are 0x80 and 0x90, respectively. Write to the R0/R1
registers in both devices to change the device address
of the MAX9249 or GMSL deserializer.
2
C or the GMSL UART format. A bypass mode enables
(MSB FIRST)
Register Mapping
15