SI3016-F-FS Silicon Laboratories Inc, SI3016-F-FS Datasheet - Page 29

IC ISOMODEM LINE-SIDE DAA 16SOIC

SI3016-F-FS

Manufacturer Part Number
SI3016-F-FS
Description
IC ISOMODEM LINE-SIDE DAA 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheet

Specifications of SI3016-F-FS

Package / Case
16-SOIC (3.9mm Width)
Data Format
V.90
Baud Rates
56k
Interface
Serial
Voltage - Supply
3.3V, 5V
Mounting Type
Surface Mount
Product
Modem Chip
Supply Current
0.3 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Register 5. DAA Control 1
Reset settings = 0000_0000
Bit
7
6
5
4
3
2
1
0
Name
Type
Bit
Reserved Read returns zero.
Reserved Read returns zero.
Reserved Read returns zero.
ONHM
Name
RDTN
RDTP
RDT
OH
D7
Ring Detect Signal Negative.
0 = No negative ring signal is occurring.
1 = A negative ring signal is occurring.
Ring Detect Signal Positive.
0 = No positive ring signal is occurring.
1 = A positive ring signal is occurring.
On-Hook Line Monitor.
0 = Normal on-hook mode.
1 = Enables low-power monitoring mode allowing the DSP to receive line activity without
going off-hook. This mode is used for caller-ID detection.
When MODE bit = 1 (Register 18, bit 2), the device consumes ~7 µA from the phone line
when in on-hook line monitor mode. When MODE = 0, the device consumes ~450 µA from
the phone line when in on-hook line monitor mode.
Note: This bit should be cleared before setting the OH bit.
Ring Detect.
0 = Reset either 4.5–9 seconds after last positive ring is detected or when the system exe-
cutes an off-hook.
1 = Indicates a ring is occurring.
Off-Hook.
0 = Line-side device on-hook.
1 = Causes the line-side chip to go off-hook. This bit operates independently of the OHE bit
and is a logic OR with the off-hook pin when enabled. When the MODE bit (Register 12, bit 2)
is set to 1, the device will go on-hook without enabling the off-hook counter, thus allowing the
device to go immediately (i.e., no timeout required on the counter) back off-hook when the
MODE bit is cleared. This is useful in supporting Type II caller ID.
Note: The ONHM bit should be cleared before setting this bit.
RDTN
D6
R
RDTP
D5
R
Rev. 1.0
D4
Function
ONHM
R/W
D3
RDT
D2
R
D1
Si3016
R/W
OH
D0
29