AN19DN0A5E020 Eaton / Control Automation, AN19DN0A5E020 Datasheet - Page 14

no-image

AN19DN0A5E020

Manufacturer Part Number
AN19DN0A5E020
Description
NEMA STARTER, SIZE 1, WITH C440 ELECTRONIC OVERLOAD RELAY, (4-20A), FLA, 120VAC COIL
Manufacturer
Eaton / Control Automation
Datasheet

Specifications of AN19DN0A5E020

Lead Free Status / Rohs Status
RoHS Compliant part
Electronic Overload Relays up to 1500A, continued
Description
Electrical/EMC
Radiated emissions
Conducted emissions
ESD immunity
Radiated immunity
Conducted immunity
Fast transient immunity
Surge immunity
Power freq. magnetic field immunity
Electromagnetic field
Distortion IEEE 519
Electrostatic discharge (ESD)
Electrical fast transient (EFT)
Surge immunity
IEC 60947-4-1-Table 15
EN 55011 (CISPIR 11) Group 1, Class A, ISM
IEC 60947-4-1-Table 14
EN 55011 (CISPIR 11) Group 1; Class ISM
IEC 60947-4-1 (Table 13)
IEC 60947-4-1
IEC 61000-4-3
IEC 60947-4-1, IEC 61000-4-6
IEC 60947-4-1 (Table 13)
IEC 61000-4-4
IEC 60947-4-1 (Table 13)
IEC 61000-4-5 a Class 4
IEC 60947-4-1, IEC 61000-4-8
IEC 60947-4-1 Table 13, IEC 61000-4-3
IEC 61000-4-2, EN 61131-2
IEC 61000-4-4, EN 61131-2
IEC 61000-4-5, EN 61131-2
Motor Protection and Monitoring
Specification
45 mm
30 mHz to 1000 mHz
0.15 mHz to 30 mHz
±8 kV air, ±6 kV contact
10 V/m 80 mHz–1000 mHz
3 V/m from 1.4 to 2.7 gHz
80% amplitude modulated
1 kHz sine wave
140 dub (10V rms)
150 kHz–100 mHz
±4 kV using direct method
±2 kV using direct method
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)
With accessory installed in expansion bay:
±2 kV line-to-line (DM) –>1.2/50 us;
2 kV line-to-earth, 1 kV line-to-line
±4 kV line-to-ground (CM)
30 A/m, 50 Hz
10 V/m
5% THD max., 5th harmonic 3% max.
4 kV contact
8 kV air discharge
±2 kV using direct method
±2 kV line-to-ground (CM)
Control Products Catalog CA08102001E—June 2010 www.eaton.com
with accessory installed in expansion bay
C440/ XT Electronic Overload Relay
55 mm
30 mHz to 1000 mHz
0.15 mHz to 30 mHz
±8 kV air, ±6 kV contact
10 V/m 80 mHz–1000 mHz
3 V/m from 1.4 to 2.7 gHz
80% amplitude modulated
1 kHz sine wave
140 dub (10V rms)
150 kHz–100 mHz
±4 kV using direct method
±2 kV using direct method
Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)
With accessory installed in expansion bay:
±2 kV line-to-line (DM) –>1.2/50 us;
2 kV line-to-earth, 1 kV line-to-line
±4 kV line-to-ground (CM)
30 A/m, 50 Hz
10 V/m
5% THD max., 5th harmonic 3% max.
4 kV contact
8 kV air discharge
±2 kV using direct method
±2 kV line-to-ground (CM)
with accessory installed in expansion bay
42.1
15
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42

Related parts for AN19DN0A5E020