PYF08-S Omron Automation, PYF08-S Datasheet - Page 17

no-image

PYF08-S

Manufacturer Part Number
PYF08-S
Description
Socket, Relay; 2; TRACK; MY4; -55 TO DEGC; GENERAL PURPOSE
Manufacturer
Omron Automation
Datasheet

Specifications of PYF08-S

Mounting
DIN Rail
Mounting Type
Track
Number Of Poles
2
Relay Type
General Purpose
Standards
UL Recognized, CSA Certified, LR, VDE Approved
Temperature, Ambient
-55 to +70 °C
Termination
Box Clamp
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
MY4
Examples of Applicable Wires (Confirmed Using Catalog Information)
■ Wiring
Use wires of the applicable sizes specified above. The length of the
exposed conductor should be 8 to 9 mm.
Use the following wiring procedure.
1. Insert the specified screwdriver into the release hole located
Fig. 2 Wire Connection Holes and Release Holes
Wire connection holes
Type of wire
Equipment wire 2491X
BS6004
Switchgear BS6231
Switchgear BS6231
Tri-rated control and switchgear
Conduit
UL1007
UL1015
UL1061
UL1430
Fig. 1 Exposed Conductor Length
Fig. 3 Section A-A of Fig. 2
beside the wire connection hole where the wire is to be inserted.
Release holes
8 to 9 mm
Wire connection hole
Release hole
Conductor type
Flexible
Solid
Flexible
Stranded
Flexible
Flexible
Flexible
Flexible
Solid
Flexible
Screwdriver
Insert
See note 1, above.
0.5 mm
18AWG
18AWG
18AWG
2
2. Insert the exposed conductor into the wire connection hole.
3. Pull out the screwdriver.
Note: Use no more than 2 wires per terminal, 1 wire per hole.
Recommended wire sizes See note 2, above.
0.5, 0.75, 1.0 mm
1.0 mm
0.5, 0.75 mm
0.5, 0.75, 1.0, 1.5 mm
1.5 mm
16AWG
18AWG, 16AWG
16AWG
General-purpose Relay
2
2
2
2
2
Insert
1.5 mm
1.5 mm
1.0 mm
MY
2
2
2
Pull out
275

Related parts for PYF08-S