PYF08-S Omron Automation, PYF08-S Datasheet

no-image

PYF08-S

Manufacturer Part Number
PYF08-S
Description
Socket, Relay; 2; TRACK; MY4; -55 TO DEGC; GENERAL PURPOSE
Manufacturer
Omron Automation
Datasheet

Specifications of PYF08-S

Mounting
DIN Rail
Mounting Type
Track
Number Of Poles
2
Relay Type
General Purpose
Standards
UL Recognized, CSA Certified, LR, VDE Approved
Temperature, Ambient
-55 to +70 °C
Termination
Box Clamp
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
MY4
Versatile, Multi-featured, Miniature Power Relay
for Sequence Control and Power Switching
Applications
• Models with lockable test buttons now available.
• Multiple features available, including operation indicators (mechan-
• Environment-friendly cadmium-free contacts.
• Wide range of Sockets (PY, PYF Series) and optional parts.
• Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A
• Provided with nameplate.
• RoHS Complaint.
Ordering Information
■ Relays
Standard Coil Polarity
Reverse Coil Polarity
Note: 1. When ordering, add the rated coil voltage to the model number(s), followed by “(S)”. Rated coil voltages are given in the coil ratings table.
Type
Standard
With built-in diode
(DC only)
With built-in CR
(220/240 VAC,
110/120 VAC only)
Type
Standard (DC only)
With built-in diode
(DC only)
ical and LED indicators), lockable test button, built-in diode and CR
(surge suppression), bifurcated contacts, etc.
General-purpose Relay
MY
2. Arc barrier standard on all four-pole relays.
3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for details.
Example: MY2 AC12(S)
Rated coil voltage
Contact form
DPDT
4PDT
4PDT (bifurcated)
DPDT
4PDT
4PDT (bifurcated)
DPDT
4PDT
4PDT (bifurcated)
Contact form
DPDT
4PDT
4PDT (bifurcated)
DPDT
4PDT
4PDT (bifurcated)
Model
Plug-in socket/solder terminals
Standard with LED
indicator
MY2N
MY4N
MY4ZN
MY2N-D2
MY4N-D2
MY4ZN-D2
MY2N-CR
MY4N-CR
MY4ZN-CR
Model
Plug-in socket/solder terminals
With LED indicator
MY2N1
MY4N1
MY4ZN1
MY2N1-D2
MY4N1-D2
MY4ZN1-D2
With LED indicator and
lockable test button
MY2IN
MY4IN
MY4ZIN
MY2IN-D2
MY4IN-D2
MY4ZIN-D2
MY2IN-CR
MY4IN-CR
MY4ZIN-CR
General-purpose Relay
With LED indicator and
lockable test button
MY2IN1
MY4IN1
MY4ZIN1
MY2IN1-D2
MY4IN1-D2
MY4ZIN1-D2
Without LED indicator
MY2
MY4
MY4Z
---
---
---
---
---
---
MY
LR
259

Related parts for PYF08-S

PYF08-S Summary of contents

Page 1

... Note: 1. When ordering, add the rated coil voltage to the model number(s), followed by “(S)”. Rated coil voltages are given in the coil ratings table. Example: MY2 AC12(S) ↑ Rated coil voltage 2. Arc barrier standard on all four-pole relays. 3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for details. Model Plug-in socket/solder terminals ...

Page 2

Specifications ■ Coil Ratings Rated voltage Rated current 214.1 mA 183 106 53 48/50 V* 24.7/ 21.1/ 25.7 mA 22.0 mA 110/120 ...

Page 3

... Precautions Connections Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators or high-sensitivity DC-operated Relays. Mounting Whenever possible, mount Relays so that it is not subject to vibration or shock in the same direction as that of contact movement. 100 mΩ max max max. 1,800 operations/hr (under rated load) 1,000 MΩ ...

Page 4

Engineering Data ■ Maximum Switching Power MY2 AC resistive load AC inductive load (cosφ=0.4) DC resistive load DC inductive load (L/R=7 ms) Switching voltage (V) ■ Endurance MY2 (Resistive Loads) 10000 5000 3000 250 VAC 1000 30 VDC 500 30 ...

Page 5

MY4Z (Resistive Loads) 10000 5000 3000 1000 250 VAC 500 300 30 VDC 100 30 VDC 50 250 VAC 30 10 Switching Current (A) MY4Z (Inductive Loads) 10000 5000 3000 1000 30 VDC 500 300 30 VDC 100 250 VAC ...

Page 6

Dimensions Note: All units are in millimeters unless otherwise indicated. ■ 2-Pole Models MY2N ■ 4-Pole Models MY4N ■ Models with Test Button MY2IN MY4IN 264 General-purpose Relay 2.6 Eight, 1.2 dia. × 2.2 long holes 0.5 28 max. 6.4 ...

Page 7

Terminal Arrangement/Internal Connections (Bottom View) MY2 MY2N/MY2IN (AC Models) MY2N-CR/MY2IN-CR (AC Models Only) MY4(Z) MY4(Z)N/MY4(Z)IN (AC Models) MY4(Z)N-CR/MY4(Z)IN-CR (AC Models Only) MY2N/MY2IN MY2N-D2/MY2IN-D2 (DC Models) (DC Models Only) MY2N1/MY2IN1 MY2N1-D2/MY2IN1-D2 (DC Models Only) (DC Models Only) MY4(Z)N/MY4(Z)IN MY4(Z)N-D/MY4(Z)IN-D2 (DC ...

Page 8

... The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. 3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55°C. 4. When using the PYF08A-N or PYF14A operating ambient temperature exceeding 40°C, reduce the current to 60%. 5. The MY2(S) can be used at 70°C with a carry current ...

Page 9

... Mounting Plates for Sockets Socket model For 1 socket PY08, PY14 PYP-1 Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets. ■ DIN Rail Track and Accessories Description Mounting rail (length = 500 mm) Mounting rail (length = 1,000 mm) End Plate Spacer ...

Page 10

... Dimensions Unit: mm (inch) Socket Dimensions PYF08A-E Two, 4 Eight mounting sems screws holes 72 max. 23 max. PYF14A-E Two, 4 mounting holes 72 max. 29.5 max. PY08/PY08-Y1 (See note) 42 max. Note: The PY08-Y1 includes sections indicated by dotted lines. PY08-02 16.5 max. 268 General-purpose Relay Terminal arrangement/ ...

Page 11

... Socket Dimensions PYF08A-N 22 max max. PYF-08A PYF14A PYF-14A 29.5 max. PY14/PY14-Y1 (See note) 42 max. Note: The PY14-Y1 includes sections indicated by dotted lines. PY14-02 16.5 max. Note: Use a panel with plate thickness for mounting the Sockets. Terminal arrangement/ internal connections (top view) ...

Page 12

... Socket Dimensions PYF14S 31 max. 85 max. PYF08S 23.2 max. 85 max. Socket Bridge Insulating coating L 1.4 dia. conductor (See note 1.) Model number Length L (mm) PYDM-14SR 27.5±0.3 PYDM-14SB PYDM-08SR 19.7±0.3 PYDM-08SB Note: 1. The relationship between the model number, the length L, and the color of the insulating coating is shown above. ...

Page 13

... Hold-down Clips PYC-A1 PYC-A1 (2 pcs per set) (2 pcs per set) 36.3 4.5 1.2 4.5 PYC-P PYC max. 3.3 38.5 PYCM-08S PYF08S Lever 28 typ. 52.5 typ. 3 typ. 29.6 typ. PYC-E1 PYC-E1 (2 pcs per set) (2 pcs per set) 5.75 ±0.1 4.5 PYC-P2 PYC- typ. ...

Page 14

... Mounting Plates for Back-connecting Sockets PYP-1 PYP-1 Two, 3.4-dia. holes t=1.6 PYP-18 PYP-18 72 elliptical holes ■ Mounting Track and Accessories DIN Rail Track PFP-50N/PFP-100N Note: The figure in the parentheses is for PFP-50N. PFP-100N2 End Plate PFP-M 272 General-purpose Relay PYP-36 PYP-36 72 elliptical holes 4 ...

Page 15

Spacer PFP-S ■ Approved Standards VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435) No. of poles Coil ratings 2 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 4 6, 12, 24, 48, 100/110, 125 VDC UL Recognized (File ...

Page 16

SEV Listings (File No. 99.5 50902.01) No. of poles Coil ratings 240 VAC 6 to 125 VDC 4 Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may ...

Page 17

Examples of Applicable Wires (Confirmed Using Catalog Information) Type of wire Conductor type Equipment wire 2491X Flexible BS6004 Solid Switchgear BS6231 Solid Switchgear BS6231 Flexible Tri-rated control and switchgear Flexible Conduit Stranded UL1007 Flexible UL1015 Flexible UL1061 Flexible UL1430 Flexible ...

Page 18

... General-purpose Relay General Precautions • Use the clip to prevent relays floating or falling out of the socket. • Do not use the product if it has been dropped on the ground. Drop- ping the product may adversely affect performance. • Confirm that the socket is securely attached to the mounting track before wiring ...

Page 19

Omron Electronic Components, LLC Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer ...

Page 20

... It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons our prac- tice to change part numbers when published ratings or features are changed, or when significant construction changes are made ...

Related keywords