ITV2050-31N2L4 SMC Corporation, ITV2050-31N2L4 Datasheet - Page 5

no-image

ITV2050-31N2L4

Manufacturer Part Number
ITV2050-31N2L4
Description
Regulator; 1500L/min; .005-.9MPa range; 24VDC; 1/4NPT ports; 1-5VDC out
Manufacturer
SMC Corporation
Datasheet

Specifications of ITV2050-31N2L4

Height
93 mm
Length
50 mm
Pressure, Operating
0.9 Mpa
Proof Pressure
0.1 MPa
Size, Port
1⁄4 "
Temperature, Ambient
0 to 50 °C
Thread Type
NPT
Working Principle
When the input signal rises, the air supply soloenoid valve q turns ON. Due to this, part of the supply pressure passes through
the air supply solenoid valve q and changes to output pressure. This product pressure feeds back to the control circuit r via the
pressure sensor e. Here, pressure corrections continue until output pressure becomes proportional to the input signal, enabling
output pressure that is proportional to the input signal.
Block diagram
Diagram of working principle
Input signal
q Air supply solenoid valve
SUP
EXH
+
Compact Electro-pneumatic Regulator
Power supply
Input signal
r Control circuit
e Pressure sensor
r Control circuit
Power supply and error
LED indication
Discharged to atmosphere
solenoid valve
solenoid valve
Supply pressure
q Air supply
w Exhaust
Output signal
w Exhaust solenoid valve
Series
OUT
e Pressure sensor
Output pressure
ITV0000