Description
Regulator; 1500L/min; .005-.9MPa range; 24VDC; 1/4NPT ports; 1-5VDC out
Manufacturer
SMC Corporation
Datasheet

Specifications of ITV2050-31N2L4

Height
93 mm
Length
50 mm
Pressure, Operating
0.9 Mpa
Proof Pressure
0.1 MPa
Size, Port
1⁄4 "
Temperature, Ambient
0 to 50 °C
Thread Type
NPT
SMC REGULATOR
ITV2000
Series
Series ITV1000
Series ITV2000
Series ITV3000
Series ITV209
With a simplified high-density circuit
board design, an extremely compact
size has been achieved.
Controls air pressure steplessly in
proportion to an electric signal.
Controls air pressure steplessly in
proportion to an electric signal.
Controls air pressure steplessly in
proportion to an electric signal.
Controls vacuum pressure steplessly
in proportion to an electric signal.
ITV0000
Series
Electro-pneumatic Regulator
Electronic Vacuum Regulator
Series
ITV001
ITV003
ITV005
ITV009
ITV101
ITV103
ITV105
ITV201
ITV203
ITV205
ITV301
ITV303
ITV305
ITV209
Model
ITV
Regulating pressure range
0.005 to 0.1 MPa
0.005 to 0.5 MPa
0.005 to 0.9 MPa
0.005 to 0.1 MPa
0.005 to 0.5 MPa
0.005 to 0.9 MPa
–1.3 to –80 kPa
0.001 to 0.1 MPa
0.001 to 0.5 MPa
0.001 to 0.9 MPa
–1 to –100 kPa
0.005 to 0.1 MPa
0.005 to 0.5 MPa
0.005 to 0.9 MPa
Inch size: ø5/32
One-touch fitting
Metric size: ø4
1/4, 3/8, 1/2
Port size
1/8, 1/4
1/4, 3/8
Built-in
1/4
14-8-14
14-8-14
14-8-14
14-8-30
Page
14-8-2
14-8-1
F.R.L.
AV
AU
AF
AR
IR
VEX
AMR
ITV
IC
VBA
VE„
VY1
G
PPA
AL

Related parts for ITV2050-31N2L4

ITV2050-31N2L4 Summary of contents

Page 1

SMC REGULATOR Electro-pneumatic Regulator ITV2000 Electronic Vacuum Regulator Series Series Series ITV0000 With a simplified high-density circuit board design, an extremely compact size has been achieved. Series ITV1000 Controls air pressure steplessly in proportion to an electric signal. Series ITV2000 ...

Page 2

Compact Electro-pneumatic Regulator Series 15 Compact With a simplified high-density circuit board design, an extremely compact size has been achieved. Realizes space-savings and reduction of weight for manifold use. Stations can easily be increased or decreased due to DIN rail ...

Page 3

Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold ITV00 1 0 Pressure range Power supply voltage 1 0.1 MPa 24 VDC ±10 0.5 MPa ∗ VDC 5 0.9 MPa ∗ ...

Page 4

ITV0000 Series Option Bracket Flat bracket assembly P39800022 L-bracket assembly P39800023 Tighting torque when assembling is 0.3 N·m. 14-8-4 Specifications Model ITV001 Min. supply pressure Max. supply pressure 0.2 MPa Regulating pressure range 0.001 to 0.1 MPa 3.5 /min(ANR) l ...

Page 5

Compact Electro-pneumatic Regulator Working Principle When the input signal rises, the air supply soloenoid valve q turns ON. Due to this, part of the supply pressure passes through the air supply solenoid valve q and changes to output pressure. This ...

Page 6

ITV0000 Series Series ITV001„ Linearity, Hyteresis 1 0.8 0.6 0.4 Return 0.2 0 –0.2 –0.4 Out –0.6 –0.8 – Input signal (%F.S.) Pressure Characteristics 1 0.5 Out 0 Return –0.5 –1 0.15 0.16 0.17 Supply pressure (MPa) ...

Page 7

Compact Electro-pneumatic Regulator Series ITV005„ Linearity, Hyteresis 1 0.8 0.6 Return 0.4 0.2 0 Out –0.2 –0.4 –0.6 –0.8 – Input signal (%F.S.) Pressure Characteristics 1 0.5 Out 0 Return –0.5 –1 0.4 0.6 0.8 Supply pressure ...

Page 8

ITV0000 Series Dimensions For Single Unit L-bracket (Option Cable connection thread Port Location No. 1 ITV00 3 OUT SUP EXH 5 ITV009 VAC ATM Note) When useing under the conditions equivalent to Breathing hole ...

Page 9

Compact Electro-pneumatic Regulator Dimensions Single unit for manifold 15 Note) Breathing hole (M3 x 0.5) OUT port (ø4, ø5/32") 2 Note) When useing under the conditions equivalent to IP65, connect the fitting or tube to the bleed hole prior to ...

Page 10

ITV0000 Series Dimensions Manifold Port Location No. 1 ITV00 3 SUP EXH OUT 5 ITV009 VAC ATM Note) Stations are counted starting from the D side Dimensions in inch are noted in parentheses. SUP, VACzport ...

Page 11

Compact Electro-pneumatic Regulator Be sure to read before handling. Precautions. Air Supply Caution 1. Install an air filter near this product on the supply side. Select a filtration degree of 5 µm or less. 2. Compressed air containing large amounts ...

Page 12

Electro-pneumatic Regulator Series Stepless control of air pressure proportional to an electrical signal ITV1000 ∗ 200 /min (ANR ...

Page 13

Electro-pneumatic Regulator ITV1000/2000/3000 Straight type Right angle type JIS Symbol Rated pressure This range is outside of the control (output). 0.005 MPa 0 0 100 Input signal (%F.S.) Graph (1) Input/output characteristics chart ITV 3 0 Model Pressure range 1 ...

Page 14

Electro-pneumatic Regulator SMC REGULATOR r Spacer ITV20 ITV2000 eL-bracket 178 qAF30 wAFM30 REGULATOR ITV30 ITV3000 234 qAF40 wAFM40 Accessory (Option)/Part No. Part no. Description ITV10 ITV20 ITV30 P3020114 Flat bracket (Mounting thread is not included.) INI-398-0-6 L-bracket (Mounting thread is ...

Page 15

ITV1000/2000/3000 Series Working Principle When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF. Therefore, supply pressure passes through the air supply solenoid valve q and is applied to ...

Page 16

Electro-pneumatic Regulator Series ITV101 Linearity 0.10 0.08 0.06 0.04 0.02 0. 100 Input signal (%F.S.) Set pressure: Pressure Characteristics 0.05 MPa 1.0 0.5 Set point 0.0 –0.5 –1.0 0.0 0.1 0.2 0.3 Supply pressure (MPa) Series ...

Page 17

ITV1000/2000/3000 Series Series ITV301 Linearity 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0. 100 Input signal (%F.S.) Set pressure: Pressure Characteristics 0.05 MPa 1.0 0.5 Set point 0.0 –0.5 –1.0 0.0 0.1 0.2 ...

Page 18

Electro-pneumatic Regulator Series ITV103 Linearity 0.6 0.5 0.4 0.3 0.2 0.1 0 100 Input signal (%F.S.) Set pressure: Pressure Characteristics 0.2 MPa 1.0 0.5 Set point 0.0 –0.5 –1.0 0.2 0.4 0.6 0.8 Supply pressure (MPa) ...

Page 19

ITV1000/2000/3000 Series Series ITV303 Linearity 0.6 0.5 0.4 0.3 0.2 0.1 0 100 Input signal (%F.S.) Set pressure: Pressure Characteristics 0.2 MPa 1.0 0.5 Set point 0.0 –0.5 –1.0 0.2 0.4 0.6 Supply pressure (MPa) 14-8-20 ...

Page 20

Electro-pneumatic Regulator Series ITV105 Linearity 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 100 Input signal (%F.S.) Set pressure: Pressure Characteristics 0.4 MPa 1.0 0.5 Set point 0.0 –0.5 –1.0 0.4 0.6 0.8 ...

Page 21

ITV1000/2000/3000 Series Series ITV305 Linearity 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 100 Input signal (%F.S.) Set pressure: Pressure Characteristics 0.4 MPa 1.0 0.5 Set point 0.0 –0.5 –1.0 0.4 0.6 0.8 ...

Page 22

Electro-pneumatic Regulator Dimensions ITV10 Flat bracket 50 RESET SET UNLOCK LOCK Setting part 84 100 REGULATOR P MPa ITV10 INPUT 0~10VDC OUTPUT 0.005~0.5MPa M3 x 0.5 GY MADE IN JAPAN Solenoid valve EXH G SUP (1) ...

Page 23

ITV1000/2000/3000 Series Dimensions ITV20 Flat bracket 50 RESET SET UNLOCK LOCK 84 100 SMC REGULATOR ITV2000 M5 x 0.8 Solenoid valve EXH SUP (1) OUT (2) 36 L-bracket G (10) 30 (7) 36 14-8-24 Note) Do not attempt to rotate, ...

Page 24

Electro-pneumatic Regulator Dimensions ITV30 Flat bracket ø7 40 Mounting hole RESET SET UNLOCK LOCK E SMC REGULATOR P ITV3000 M5 x 0.8 Solenoid valve EXH G SUP (1) SUP (2) L-bracket G (10) 30 (7) 36 ITV1000/2000/3000 ...

Page 25

ITV1000/2000/3000 Series Specific Product Precautions 1 Be sure to read before handling. Operating Environment Warning 1. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. 2. Consult SMC when used in ...

Page 26

ITV1000/2000/3000 Series Specific Product Precautions 2 Be sure to read before handling. Caution Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC ...

Page 27

Electronic Vacuum Regulator Series í Stepless control of vacuum pressure in proportion to an electric signal Straight type Right angle type Piping/Wiring Diagram Input signal (VDC, mADC) VAC OUT Tank ITV2090 Vacuum pump, Set pressure Ejector (Vacuum) ITV 209 0 ...

Page 28

Working Principle Pressure display Power supply i Control circuit Input signal q Vacuum pressure solenoid valve r Diaphragm VAC (Vacuum pump, etc.) ATM (Atmospheric pressure) Series ITV209„ Linearity 0 –20 –40 –60 – 100 Input signal ...

Page 29

Dimensions ITV2090 „50 RESET SET UNLOCK LOCK 84 100 E SMC P REGULATOR ITV2090 G ATM (Atmospheric pressure) „36 G (10) 30 (7) 36 14-8-32 Note) Do not attempt to rotate the cable connector does not turn. Cable ...

Page 30

Accessory (Option)/Part No. Description Part no. Flat bracket P3020114 L-bracket INI-398-0-6 Straight type TM-4DSX3HG4 Cable connector Right angle type TM-4DLX3HG4 Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. Caution 1. ...

Page 31

Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. Caution Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring ...

Page 32

Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 JIS ...

Page 33

Common Precautions Be sure to read before handling. For detailed precautions on every series, refer to main text. Selection Warning 1. Confirm the specifications. Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), ...

Page 34

Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SMC has obtained certification for international standards “ISO 9001” and ...

Page 35

SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied. It has been obligatory to apply CE ...

Page 36

Standards you to comply with EC directives and CSA/UL standards. í CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly ...

Page 37

... SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 MEXICO SMC Corporation (Mexico), S.A. DE C.V. Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 CHILE SMC Pneumatics (Chile) S ...

Page 38

... SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 PHILIPPINES SHOKETSU SMC Corporation Unit 201 Common Goal Tower, Madrigal Business Park, Ayala Alabang Muntinlupa, Philippines TEL: 02-8090565 FAX: 02-8090586 MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. ...

Related keywords