MAX5945EAX+ Maxim Integrated Products, MAX5945EAX+ Datasheet - Page 22

IC NETWORK PWR CTRL 36-SSOP

MAX5945EAX+

Manufacturer Part Number
MAX5945EAX+
Description
IC NETWORK PWR CTRL 36-SSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX5945EAX+

Controller Type
Network Power Controller
Interface
I²C
Voltage - Supply
3.3V
Current - Supply
4.2mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
36-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MAX5945 reads using the MAX5945’s internally
stored command byte as an address pointer, the same
way the stored command byte is used as an address
pointer for a write. The pointer auto-increments after
reading each data byte using the same rules as for a
write. Thus, a read is initiated by first configuring the
MAX5945’s command byte by performing a write
(Figure 12). The master now reads ‘n’ consecutive
bytes from the MAX5945, with the first data byte read
from the register addressed by the initialized command
byte (Figure 13). When performing read-after-write veri-
fication, remember to reset the command byte’s
address because the stored control byte address auto-
increments after the write.
When the MAX5945 operates on a 2-wire interface with
multiple masters, a master reading the MAX5945
should use repeated starts between the write that sets
the MAX5945’s address pointer, and the read(s) that
takes the data from the location(s). It is possible for
master 2 to take over the bus after master 1 has set up
the MAX5945’s address pointer but before master 1
has read the data. If master 2 subsequently resets the
MAX5945’s address pointer then master 1’s read may
be from an unexpected location.
Address auto-incrementing allows the MAX5945 to be
configured with fewer transmissions by minimizing the
number of times the command address needs to be
sent. The command address stored in the MAX5945
generally increments after each data byte is written or
read (Table 4). The MAX5945 is designed to prevent
overwrites on unavailable register addresses and unin-
tentional wrap-around of addresses.
Quad Network Power Controller
for Power-Over-LAN
Table 4. Auto-Increment Rules
22
0x00 to 0x26
0x26
ADDRESS RANGE
COMMAND BYTE
______________________________________________________________________________________
Command Address Auto-Incrementing
Operation with Multiple Masters
Command address will auto-
increment after byte read or written
Command address remains at 0x26
after byte written or read
AUTO-INCREMENT BEHAVIOR
Message Format for Reading
The interrupt register (Table 5) summarizes the event
register status and is used to send an interrupt signal
(INT goes low) to the controller. Writing a 1 to R1Ah[7]
clears all interrupt and events registers. A reset sets
R00h to 00h.
INT_EN (R17h[7]) is a global interrupt mask (Table 6).
The MASK_ bits activate the corresponding interrupt
bits in register R00h. Writing a 0 to INT_EN (R17h[7])
disables the INT output.
A reset sets R01h to AAA00A00b, where A is the state
of the AUTO input prior to the reset.
The power event register (Table 7) records changes in
the power status of the four ports. Any change in
PGOOD_ (R10h[7:4]) sets PG_CHG_ to 1. Any change
in the PWR_EN_ (R10h[3:0]) sets PWEN_CHG_ to 1.
PG_CHG_ and PWEN_CHG_ trigger on the edges of
PGOOD_ and PWR_EN_ and do not depend on the
actual level of the bits. The power event register has
two addresses. When read through the R02h address,
the content of the register is left unchanged. When read
through the CoR R03h address, the register content will
be cleared. A reset sets R02h/R03h = 00h.
DET_END_/CL_END_ is set high whenever detection/
classification is completed on the corresponding port.
A 1 in any of the CL_END_ bits forces R00h[4] to 1. A 1
in any of the DET_END_ bits forces R00h[3] to 1. As
with any other events register, the detect event register
(Table 8) has two addresses. When read through the
R04h address, the content of the register is left
unchanged. When read through the CoR R05h
address, the register content will be cleared. A reset
sets R04h/R05h = 00h.
LD_DISC_ is set high whenever the corresponding port
shuts down due to detection of load removal.
IMAX_FLT_ is set high when the port shuts down due to
an extended overcurrent event after a successful start-
up. A 1 in any of the LD_DISC_ bits forces R00h[2] to 1.
A 1 in any of the IMAX_FLT_ bits forces R00h[5] to 1.
As with any of the other events register, the fault event
register (Table 9) has two addresses. When read
through the R06h address, the content of the register is
left unchanged. When read through the CoR R07h
address, the register content will be cleared. A reset
sets R06h/R07h = 00h.
Register Map And Description

Related parts for MAX5945EAX+