DS18S20 Maxim Integrated Products, DS18S20 Datasheet - Page 15

no-image

DS18S20

Manufacturer Part Number
DS18S20
Description
Board Mount Temperature Sensors
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS18S20

Full Temp Accuracy
+/- 2 C
Package / Case
TO-92
Digital Output - Bus Interface
Serial (1-Wire)
Digital Output - Number Of Bits
9 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS18S20
Manufacturer:
SHARP
Quantity:
17 690
Part Number:
DS18S20
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS18S20+
Manufacturer:
Maxim
Quantity:
12 047
Part Number:
DS18S20+
Manufacturer:
DIODES
Quantity:
6 000
Part Number:
DS18S20+
Manufacturer:
MAXIM
Quantity:
8 000
Part Number:
DS18S20+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20+PAR
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20+T&R
Manufacturer:
MAXIM
Quantity:
4 000
Part Number:
DS18S20+T&R
0
Part Number:
DS18S20+TR
Manufacturer:
ST
Quantity:
2 191
Part Number:
DS18S20Z
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20Z+
Manufacturer:
Maxim
Quantity:
2 943
Part Number:
DS18S20Z+T&R
Manufacturer:
MAXIM
Quantity:
500
Part Number:
DS18S20Z+T&R
0
1-WIRE SIGNALING
The DS18B20 uses a strict 1-Wire communication protocol to ensure data integrity. Several signal types
are defined by this protocol: reset pulse, presence pulse, write 0, write 1, read 0, and read 1. The bus
master initiates all these signals, with the exception of the presence pulse.
INITIALIZATION PROCEDURE—RESET AND PRESENCE PULSES
All communication with the DS18B20 begins with an initialization sequence that consists of a reset pulse
from the master followed by a presence pulse from the DS18B20. This is illustrated in Figure 13. When
the DS18B20 sends the presence pulse in response to the reset, it is indicating to the master that it is on
the bus and ready to operate.
During the initialization sequence the bus master transmits (T
low for a minimum of 480µs. The bus master then releases the bus and goes into receive mode (R
When the bus is released, the 5kΩ pullup resistor pulls the 1-Wire bus high. When the DS18B20 detects
this rising edge, it waits 15µs to 60µs and then transmits a presence pulse by pulling the 1-Wire bus low
for 60µs to 240µs.
Figure 13. Initialization Timing
READ/WRITE TIME SLOTS
The bus master writes data to the DS18B20 during write time slots and reads data from the DS18B20
during read time slots. One bit of data is transmitted over the 1-Wire bus per time slot.
WRITE TIME SLOTS
There are two types of write time slots: “Write 1” time slots and “Write 0” time slots. The bus master
uses a Write 1 time slot to write a logic 1 to the DS18B20 and a Write 0 time slot to write a logic 0 to the
DS18B20. All write time slots must be a minimum of 60µs in duration with a minimum of a 1µs recovery
time between individual write slots. Both types of write time slots are initiated by the master pulling the
1-Wire bus low (see Figure 14).
To generate a Write 1 time slot, after pulling the 1-Wire bus low, the bus master must release the 1-Wire
bus within 15µs. When the bus is released, the 5kΩ pullup resistor will pull the bus high. To generate a
Write 0 time slot, after pulling the 1-Wire bus low, the bus master must continue to hold the bus low for
the duration of the time slot (at least 60µs).
1-WIRE BUS
GND
V
PU
MASTER T
480µs minimum
X
waits 15-60µs
RESET PULSE
DS18B20
LINE TYPE LEGEND
Bus master pulling low
DS18B20 pulling low
Resistor pullup
15 of 22
presence pulse
DS18B20 T
X
60-240µs
) the reset pulse by pulling the 1-Wire bus
480µs minimum
MASTER R
X
X
DS18B20
X
).

Related parts for DS18S20