DS18S20 Maxim Integrated Products, DS18S20 Datasheet

no-image

DS18S20

Manufacturer Part Number
DS18S20
Description
Board Mount Temperature Sensors
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS18S20

Full Temp Accuracy
+/- 2 C
Package / Case
TO-92
Digital Output - Bus Interface
Serial (1-Wire)
Digital Output - Number Of Bits
9 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS18S20
Manufacturer:
SHARP
Quantity:
17 690
Part Number:
DS18S20
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS18S20+
Manufacturer:
Maxim
Quantity:
12 047
Part Number:
DS18S20+
Manufacturer:
DIODES
Quantity:
6 000
Part Number:
DS18S20+
Manufacturer:
MAXIM
Quantity:
8 000
Part Number:
DS18S20+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20+PAR
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20+T&R
Manufacturer:
MAXIM
Quantity:
4 000
Part Number:
DS18S20+T&R
0
Part Number:
DS18S20+TR
Manufacturer:
ST
Quantity:
2 191
Part Number:
DS18S20Z
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20Z+
Manufacturer:
Maxim
Quantity:
2 943
Part Number:
DS18S20Z+T&R
Manufacturer:
MAXIM
Quantity:
500
Part Number:
DS18S20Z+T&R
0
Part Number:
DS18S20Z+TR
Manufacturer:
MAXIM
Quantity:
3 427
DESCRIPTION
The DS18B20 digital thermometer provides 9-bit
to 12-bit Celsius temperature measurements and
has an alarm function with nonvolatile user-
programmable upper and lower trigger points.
The DS18B20 communicates over a 1-Wire bus
that by definition requires only one data line (and
ground) for communication with a central
microprocessor. It has an operating temperature
range of -55°C to +125°C and is accurate to
±0.5°C over the range of -10°C to +85°C. In
addition, the DS18B20 can derive power directly
from the data line (“parasite power”), eliminating
the need for an external power supply.
Each DS18B20 has a unique 64-bit serial code,
which allows multiple DS18B20s to function on
the same 1-Wire bus. Thus, it is simple to use one
microprocessor to control many DS18B20s
distributed over a large area. Applications that
can benefit from this feature include HVAC
environmental controls, temperature monitoring
systems
machinery, and process monitoring and control
systems.
FEATURES
Unique 1-Wire® Interface Requires Only One
Port Pin for Communication
Each Device has a Unique 64-Bit Serial Code
Stored in an On-Board ROM
Multidrop Capability Simplifies Distributed
Temperature-Sensing Applications
Requires No External Components
Can Be Powered from Data Line; Power Supply
Range is 3.0V to 5.5V
Measures Temperatures from -55°C to +125°C
(-67°F to +257°F)
±0.5°C Accuracy from -10°C to +85°C
Thermometer Resolution is User Selectable
from 9 to 12 Bits
Converts Temperature to 12-Bit Digital Word in
750ms (Max)
inside
buildings,
equipment,
or
1 of 22
1-Wire is a registered trademark of Maxim Integrated Products, Inc.
PIN CONFIGURATIONS
(BOTTOM VIEW)
1-Wire Digital Thermometer
(DS18B20)
MAXIM
18B20
User-Definable Nonvolatile (NV) Alarm
Settings
Alarm Search Command Identifies and
Addresses Devices Whose Temperature is
Outside Programmed Limits (Temperature
Alarm Condition)
Available in 8-Pin SO (150 mils), 8-Pin µSOP,
and 3-Pin TO-92 Packages
Software Compatible with the DS1822
Applications Include Thermostatic Controls,
Industrial Systems, Consumer Products,
Thermometers, or Any Thermally Sensitive
System
1 2 3
1
Programmable Resolution
TO-92
2 3
GND
N.C.
N.C.
N.C.
N.C.
V
DQ
DQ
DD
SO (150 mils)
(DS18B20Z)
1
2
3
4
3
4
(DS18B20U)
1
2
µSOP
DS18B20
REV: 042208
8
7
6
5
6
8
7
5
N.C.
N.C.
N.C.
GND
V
N.C.
N.C.
N.C.
DD

Related parts for DS18S20

DS18S20 Summary of contents

Page 1

... Software Compatible with the DS1822  Applications Include Thermostatic Controls, Industrial Systems, Consumer Products, Thermometers, or Any Thermally Sensitive System PIN CONFIGURATIONS MAXIM 18B20 equipment (BOTTOM VIEW) TO-92 (DS18B20) 1-Wire is a registered trademark of Maxim Integrated Products, Inc DS18B20 N.C. N. N. GND ...

Page 2

ORDERING INFORMATION PART DS18B20 DS18B20+ DS18B20/T&R DS18B20+T&R DS18B20-SL/T&R DS18B20-SL+T&R DS18B20U DS18B20U+ DS18B20U/T&R DS18B20U+T&R DS18B20Z DS18B20Z+ DS18B20Z/T&R DS18B20Z+T&R +Denotes a lead-free package. A “+” will appear on the top mark of lead-free packages. T&R = Tape and reel. *TO-92 packages in ...

Page 3

The 1-Wire bus protocol, including detailed explanations of the commands and “time slots,” is covered in the 1-Wire Bus System section. Another feature of the DS18B20 is the ability to operate without an external power supply. ...

Page 4

Figure 2. Temperature Register Format BIT 7 BIT BYTE 2 2 BIT 15 BIT 14 MS BYTE SIGN Table 1. Temperature/Data Relationship DIGITAL OUTPUT TEMPERATURE (°C) +125 0000 0111 1101 0000 +85* 0000 ...

Page 5

The master device can check the alarm flag status of all DS18B20s on the bus by issuing an Alarm Search [ECh] command. Any DS18B20s with a set alarm flag will respond to the command, so the master can determine exactly ...

Page 6

Figure 4. Supplying the Parasite-Powered DS18B20 During Temperature Conversions µP Figure 5. Powering the DS18B20 with an External Supply µP 64-BIT LASERED ROM CODE Each DS18B20 contains a unique 64–bit code (see Figure 6) stored in ROM. The least significant ...

Page 7

MEMORY The DS18B20’s memory is organized as shown in Figure 7. The memory consists of an SRAM scratchpad with nonvolatile EEPROM storage for the high and low alarm trigger registers (T and configuration register. Note that if the DS18B20 alarm ...

Page 8

CONFIGURATION REGISTER Byte 4 of the scratchpad memory contains the configuration register, which is organized as illustrated in Figure 8. The user can set the conversion resolution of the DS18B20 using the R0 and R1 bits in this register as ...

Page 9

Application Note 27: Understanding and Using Cyclic Redundancy Checks with Maxim iButton Products. Figure 9. CRC Generator (MSB) 1-WIRE BUS SYSTEM The 1-Wire bus system uses a single bus master to control one or more slave devices. ...

Page 10

... Only the slave that exactly matches the 64-bit ROM code sequence will respond to the function command issued by the master; all other slaves on the bus will wait for a reset pulse. iButton is a registered trademark of Maxim Integrated Products, Inc. ® Book of Standards at www.maxim-ic.com/ibuttonbook. After every ...

Page 11

SKIP ROM [CCh] The master can use this command to address all devices on the bus simultaneously without sending out any ROM code information. For example, the master can make all DS18B20s on the bus perform simultaneous temperature conversions by ...

Page 12

COPY SCRATCHPAD [48h] This command copies the contents of the scratchpad T to EEPROM. If the device is being used in parasite power mode, within 10µs (max) after this command is issued the master must enable a strong pullup on ...

Page 13

Figure 11. ROM Commands Flowchart Initialization Sequence 33h N READ ROM MATCH ROM COMMAND Y MASTER T DS18B20 T X FAMILY CODE 1 BYTE DS18B20 T X SERIAL NUMBER 6 BYTES MASTER T DS18B20 T X CRC BYTE MASTER T ...

Page 14

Figure 12. DS18B20 Function Commands Flowchart 44h MASTER T CONVERT X FUNCTION TEMPERATURE COMMAND ? Y N PARASITE POWER ? DS18B20 BEGINS CONVERSION DEVICE N CONVERTING TEMPERATURE ? Y MASTER MASTER R “0s” R “1s” B4h N READ ...

Page 15

SIGNALING The DS18B20 uses a strict 1-Wire communication protocol to ensure data integrity. Several signal types are defined by this protocol: reset pulse, presence pulse, write 0, write 1, read 0, and read 1. The bus master initiates all ...

Page 16

The DS18B20 samples the 1-Wire bus during a window that lasts from 15µs to 60µs after the master initiates the write time slot. If the bus is high during the sampling window written to the DS18B20. If ...

Page 17

DS18B20 is valid for 15µs after the falling edge that initiated the read time slot. Therefore, the master must release the bus and then sample the bus state within 15µs from the start of the slot. Figure ...

Page 18

DS18B20 OPERATION EXAMPLE 1 In this example there are multiple DS18B20s on the bus and they are using parasite power. The bus master initiates a temperature conversion in a specific DS18B20 and then reads its scratchpad and recalculates the CRC ...

Page 19

ABSOLUTE MAXIMUM RATINGS Voltage Range on Any Pin Relative to Ground .................................................................. -0.5V to +6.0V Operating Temperature Range ....................................................................................... -55°C to +125°C Storage Temperature Range ........................................................................................... -55°C to +125°C Solder Temperature ..................................................... Refer to the IPC/JEDEC J-STD-020 Specification. These are ...

Page 20

AC ELECTRICAL CHARACTERISTICS—NV MEMORY PARAMETER NV Write Cycle Time EEPROM Writes EEPROM Data Retention AC ELECTRICAL CHARACTERISTICS PARAMETER Temperature Conversion Time Time to Strong Pullup On Time Slot Recovery Time Write 0 Low Time Write 1 Low Time Read Data ...

Page 21

Figure 18. Timing Diagrams DS18B20 ...

Page 22

... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time © 2008 Maxim Integrated Products DESCRIPTION Maxim is a registered trademark of Maxim Integrated Products, Inc. DS18B20 PAGES CHANGED 19 5 ...