J HOLD FUNCTIONS
Normal
Measurement is performed continuously and measurement results are displayed and output.
Peak Hold and Bottom Hold
The maximum or the minimum value while the timing input is ON is displayed, output, and held. The discrimination outputs are controlled
according to the displayed value and output value.
Sample Hold
The current value when the timing input turns ON is displayed, output, and held. The discrimination outputs are controlled according to the
displayed value and output value.
Timing input
Timing input
Power ON
or hold reset input
Power ON
or hold reset input
Sampling
Display during
this period:
The measured value is output as a linear output.
Display during
this period:
The measured value is output as a linear output.
The discrimination outputs are not turned OFF
when the timing input turns ON.
The discrimination outputs are not turned OFF
when the timing input turns ON.
Sampling
Displayed value (Output)
Measured value
Displayed value (Output)
Measured value